Participants:
* E. Adli, D. Schulte, L Rinolfi, H. Burckhard, M. Fitterer, F. Stulle, R. Tomas, B. Dalena, D. Wang
+ webex participants (please see web)
Presentations:
* K. Moffeit: Extraction line polarimeter at CLIC
* Y. Nosochkov: CLIC Distributions at IP
K. Moffeit: Extraction line polarimeter at CLIC
- presents an ILC type extraction line polarimeter and energy measurement (for CLIC crossing angle of 20 mrad)
- some differences: ILC/CLIC : CLIC higher energy weill require longer magents, CLIC large beamstrahlung mom. spread may not allow focusing system for smal beam size at Compton IP
- "cartoon" suggestion for a CLIC extraction line presented
Discussion:
- DS: difficult to find focusing for the spent beam at CLIC
Questions
Q AS: what is the purpose of photon and spent-beam separation
A DS: beamstrahlung must be used for lumonisity optimization
Y. Nosochkov: CLIC Distributions at IP
- recieved beam data from right after the IP in Guinea-Pig format from R. Tomas
- main remark 1) on amount of power in low energy tail (1 MW at /E0 < 50%)
- main remark 2) even opposite charge e's can be focused, but particles in energy tails must be collimated
Comments:
DS: A. Ferrari tried to find focusing options for spent beam, but opted for a system w/o focussing in the end - but we should still consider a focusing system
DS: Suggests K. Elsener presents the detector options in one of the next meetings
Next meeting: R. Tomas and A. Seryi when the good time for the next meeting will take place
EA, 26-nov-2008
There are minutes attached to this event.
Show them.