DEELS 21- Diagnostics Experts of European Light Sources 2021
Wednesday 7 July 2021 -
10:00
Monday 5 July 2021
Tuesday 6 July 2021
Wednesday 7 July 2021
10:00
DEELS2021 WELCOME
-
Hussein Al-Mohammad
(
SESAME
)
DEELS2021 WELCOME
Hussein Al-Mohammad
(
SESAME
)
10:00 - 10:15
10:15
Computer vision application for real-time beam tracking in pinhole image systems at Alba
-
Andriy Nosych
(
ALBA CELLS (ES)
)
Computer vision application for real-time beam tracking in pinhole image systems at Alba
(Photon beam diagnostic)
Andriy Nosych
(
ALBA CELLS (ES)
)
10:15 - 10:35
During the last year we have installed and commissioned a second x-ray pinhole at ALBA for redundant and alternative beam size measurements. Here we report the issues we encountered and compare the ultimate PSF of both pinholes at ALBA. We also report on the first steps of a computer vision and machine learning application for pinhole beam diagnostics. We have trained an artificial neural network to simultaneously detect, track and measure one or more beam images coming from the pinhole camera feed.
10:35
Discussion
Discussion
10:35 - 10:45
10:45
Photon Beam Diagnostics at SESAME
-
Omar AL KAILANI
(
SESAME
)
Photon Beam Diagnostics at SESAME
(Photon beam diagnostic)
Omar AL KAILANI
(
SESAME
)
10:45 - 11:05
Multiple systems of photon diagnostics are adapted at SESAME, in order to measure beam size and to observe the beam profile in various positions. One of the systems is the In-Air X-ray Detector (IAXD), which primarily depends on high-exposure imaging of the residual high energy x-rays that escaped after the photon absorber on the ends of the bending magnet ports. In addition to that, the Synchrotron Radiation Monitor (SRM) has been implemented in two techniques, the first is simply direct imaging of the monitor, the second is to adapt the interferometry technique to acquire beam size measurement. Other than that, Pinhole imaging system is currently being designed to be installed at cell 15, to provide precise measurement of both vertical and horizontal beam sizes through fitting formula of the obtained images.
11:05
Discussion
Discussion
11:05 - 11:15
11:15
Coffee Break
Coffee Break
11:15 - 11:35
11:40
Results with the Visible Light diagnostics with EBS now in full User-service mode
-
Elena Buratin
(
ESRF - European Synchrotron Radiation Facility
)
Results with the Visible Light diagnostics with EBS now in full User-service mode
(Photon beam diagnostic)
Elena Buratin
(
ESRF - European Synchrotron Radiation Facility
)
11:40 - 12:00
Several Visible Light diagnostics have put in operation, more than 1 year after the start of the EBS commissioning. The Visible Light extraction system, with its first mirror in UHV and a chicaned transfer line, has been completely and optimally aligned to obtain distortion-free light in a dedicated laboratory at 9m from source point. This allowed to characterize this light in different means, and to then use it for bunch-length measurements with a Streak Camera. This for both the stored bunches in the Storage Ring and for the injected bunches, with the latter showing both their bunch-length and the longitudinally behaviour of that injected beam under different injection conditions.
12:00
Discussion
Discussion
12:00 - 12:10
12:10
Experience with Pilot-tone+Libera Spark at ALBA
Experience with Pilot-tone+Libera Spark at ALBA
(BPM electronics development)
12:10 - 12:30
A BPM calibration-readout system composed by a Libera Spark and a Pilot-tone generator has been installed at ALBA. In this talk, results on stability and position measurement will be reported. A comparison of performances between this readout system and other Libera Elettronics, will also be presented.
12:30
Discussion
Discussion
12:30 - 12:40
12:50
Lunch Break
Lunch Break
12:50 - 14:00
14:05
SESAME in a Nutshell
-
Hussein Al-Mohammad
(
SESAME
)
SESAME in a Nutshell
Hussein Al-Mohammad
(
SESAME
)
14:05 - 14:20
A pre-recorded video for SESAME facility illustrating the main components and some of diagnostics instruments.
14:20
Discussion
Discussion
14:20 - 14:25
14:25
Improvements of the bunch purity measurement at PETRA III
-
Kai-Oliver Demmler
(
DESY
)
Improvements of the bunch purity measurement at PETRA III
(Others)
Kai-Oliver Demmler
(
DESY
)
14:25 - 14:45
In this presentation the actual work on the bunch purity measurement at PETRA III will be reported. The system is based on small area XAPDs used as detector in a time correlated single photon counting measurement scheme. At first improvements of the analog electronics of the detector head will be shown. An introduction to the test setup and placement at the PETRA III storage ring and the specific characteristics will be given, too. At least we will have a look on the actual results and ideas for future improvements.
14:45
Discussion
Discussion
14:45 - 14:55
14:55
About XBPMs for SOLEIL upgrade
-
Marie labat
About XBPMs for SOLEIL upgrade
(Upgrade projets)
Marie labat
14:55 - 15:15
SOLEIL Synchrotron has an upgrade plan to replace its storage ring by a new one based on multi-bend (7/4BA) achromat lattice. To fulfil the new tight requirements, most beam diagnostics will have to be replaced, or at least refurbished and improved. Among them are the X-ray Beam Position Monitors (XBPMs). Located on each beamline front-end, they enable to measure the position of the photon beams before their delivery to downstream users. The present XBPMs rely on four tungsten or copper blades operated in photo-emission mode. We will present a brief state-of-the-art of the existing or under-study XBPM systems, summarize the limitations our systems are presently facing, and introduce our strategy for the upgrade.
15:15
Discussion
Discussion
15:15 - 15:25
15:25
XBPM temperature interlocks for DLS-II
-
Chris Bloomer
(
Diamond Light Source Ltd.
)
XBPM temperature interlocks for DLS-II
(Photon beam diagnostic)
Chris Bloomer
(
Diamond Light Source Ltd.
)
15:25 - 15:45
Synchrotron upgrades at Diamond Light Source and elsewhere are being undertaken to increase the X-ray brightness. A side effect of this is an increase in power that may be intercepted by X-ray beam diagnostics. Of particular concern are front end XBPMs, often the first component along the beam path. Diamond currently uses a temperature interlock to prevent damage to XBPMs in the event of a missteer. A PT100 monitors the temperature of a water-cooled copper aperture within the XBPM, and beam is dumped if the temperature exceeds a threshold value. However, it is well understood that using this single temperature sensor as a critical MPS component is unsatisfactory. Presented in this talk are our findings on the effectiveness and limitations of our existing front end XBPM interlocks. Diamond is aiming to re-use as much of the front end as possible after our machine upgrade, and entirely replacing our XBPM apertures and fitting additional temperature sensors is undesirable. We will also present our concepts for potential future interlock triggers, and will welcome input from DEELS on their experiences with similar problems.
15:45
Discussion
Discussion
15:45 - 15:55
15:55
Conclusions
-
Hussein Al-Mohammad
(
SESAME
)
Conclusions
Hussein Al-Mohammad
(
SESAME
)
15:55 - 16:05