Particle Detection utilizing Modified Bandgap Reference Circuit Design

13 Jul 2021, 15:30
15m
Track C (Zoom)

Track C

Zoom

talk Particle Detectors Particle Detectors

Speaker

Elaine Rhoades (Georgia Institute of Technology)

Description

A novel particle detector design is proposed utilizing a modified bandgap reference circuit. The output of the circuit is calibrated to be proportional to the work function of gallium nitride, which provides a reference voltage that is independent of temperature variations, supply variations and loading. It is hypothesized that particle interactions with the detector cause temporal fluctuations in the output. Experimental data of transient signals observed under neutron and alpha irradiation are presented.

Are you are a member of the APS Division of Particles and Fields? Yes

Primary authors

Elaine Rhoades (Georgia Institute of Technology) Aaron Green (Georgia Institute of Technology) Dr William Hunt (Georgia Institute of Technology)

Presentation materials