A solid state amplifier family has been developed to provide 30kW pulsed at 352 MHz for each of the three buncher cavities of the ESS proton linac. The presentation will give an overview of the amplifiers, with a focus on the installation and tests carried out. The amplifiers are now in operation having been used initially for cavity conditioning and recently for early operation with beam. This presentation reviews the experience gained, improvements and problems solved.