Attendees: Carlos, Danilo, David, Josh, Matt, Richard, Xola

1. Humidity 
- 8 vs 10 layers for LPG
  8 layers: amplitude 15 dB, resolution < 6 nm
  12 layers: amplitude 8 dB, resolution 0.5 nm
- Grounding problem
  disucssed in the strips integration meeting
  we cannot replace the Titanium screws
  we will ground the Titanium screws 
  we agree we cannot stop the prodcuction
  we will address the grounding as post production
- Jig for production of packages
  Reduce the time from 45 min to 20 min
  And reduce the change of breaking the fibers 
  New design made by Julian
- Measurement at -20C is ongoing with first assembled package
  Ramp temperature and humidity below 5% RH
  We should have plots by Friday

2. Type 2 cables
- Environmental monitoring
  Axon AWG2619 Cable Type B
  12 wire pairs per cable
  4.5 km
- Heaters
  Axon 10xAWG26 + 4xAWG18
  Heater + control + interlock
  44 cables in total
  4.5 km from PP1 to USA15
  0.5 km from PP1 to PP2

3. Person from Javeriana will be at CERN next week
 Goal to setup a WinCC project and a OPC UA Can Server - Wilson Hernandez
 Person from Javeriana will be at CERN from March to June