Participants: D.Wollman, B.Salvachua, A.Lechner, C.Hernalsteens, C.E.Montanari, P.Hermes, N.Triantafyllou, F.Carra, S.Redaelli, R.Bruce

 

Belen first presentation:

Two corrections: luminosity in colliding IRs and IR7 from collimation

As this is done on only one energy level, it would affect only a small part in the ramp

Implement changes during the technical stop

 

C.E.Montanari presentation:

 

Loss maps 8.5 sigmas in secondaries (relaxed settings)

In B1H strong losses in IR6 too (will we quench first in IR6?)

In B1V comparable cleaning and inefficiency in the DS of IR7, but lower losses in IR6 

Still considering nominal settings for the quench test...

Rescaling to 1.2MW to have margin

In terms of BLM signals in does not change a lot if B1H or B1V

 

F.Carra presentation:

 

Considerations taken into account for the 2013 quench test

Maybe expect to reach 50C during the 2024 quench test...

Do not advise to increase temperature thresholds 

 

Second presentation Belen:

 

B1V selected!!!