Dr Ahmet รamlฤฑca (XERA Medical Systems & Technology)7/1/26, 5:35โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
The realization of large-area photon-counting X-ray detectors remains challenging due to the stringent requirements on charge transport and spectral performance. Although CdTe and CZT exhibit excellent energy-resolving capabilities, their implementation in large-area imaging systems is constrained by fabrication cost, scalability limitations, and spectral distortions associated with charge...
Go to contribution page -
Ahmet รamlฤฑca (XERA Medical Systems & Technology)7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
Spectral X-ray imaging based on single-photon-counting (SPC) detectors enables energy-resolved detection of individual X-ray photons, thereby offering substantial reductions in radiation dose together with improved tissue contrast, higher spatial resolution, and enhanced material decomposition capabilities in imaging modalities such as mammography and computed tomography (CT) [1]. However,...
Go to contribution page -
Heejeong Kim7/1/26, 5:40โฏPMImaging theoryPoster presentation only
Neutron radiography plays an important role in non-destructive evaluation, including aerospace inspection and battery analysis. Recent advances in compact accelerator-driven neutron sources and neutron flat-panel detectors (nFPDs) have improved the accessibility and performance of neutron imaging, enabling practical three-dimensional neutron computed tomography (CT). However, reducing...
Go to contribution page -
Dr Matti Kalliokoski (Helsinki Institute of Physics (FI))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Transmittance imaging enables the localization and mapping of various crystal features, such as defects and inclusions, within CdTe and CZT crystals [1]. By converting these identified locations into point clouds, we can analyse defect relationships using advanced computational tools, including neural networks. The resulting maps allow us to estimate crystal quality before the materials are...
Go to contribution page -
Chirayu Gupta (Vrije Universiteit Brussel (BE)), Saranya Nandakumar (Vrije Universiteit Brussel (BE))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
As the CMS pixel detector approaches the end of Run 3, it sustains increasing radiation damage that significantly impacts tracking performance. The resulting degradation in charge collection efficiency leads to "broken clusters" (pixels missing within a cluster) and "shorter clusters" (missing end pixels). These effects degrade track resolution and introduce substantial hit position bias,...
Go to contribution page -
Chihaya Fujiwara (Tohoku University)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Alpha particles imaging with zero-dimensional halide perovskite scintillator
Chihaya Fujiwara1,2*, Yusuke Urano3, Akihiro Yamaji4, Akira Yoshiakwa1,2 and Shunsuke Kurosawa4,5
- Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Sendai, Miyagi, 980-5877, Japan
- Department of Materials Science, Graduate School of Engineering, Tohoku University, 6-6-11 Aoba,...
-
Jan Garrevoet7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
The push for higher photon fluxes needs to be countered by development of X-ray detectors capable of processing all these photon events. Presented is a custom made monolithic silicon drift detector (SDD), that has this goal in mind.
Go to contribution page
Besides discussing the design, preliminary performance results will be discussed. -
Charles Townsend-Rose (European XFEL)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
The DSSC (DEPFET Sensor with Signal Compression) is a large-area, ultra-fast (4.5 MHz), soft X-ray (0.25 - 6 keV) camera developed for operation at the European X-ray Free Electron Laser. The pixel design features low-noise DEPFET technology with a modified doping profile that induces a signal-dependent gain, extending the detector's dynamic range. The full camera comprises 16 front-end...
Go to contribution page -
Nina Dimova7/1/26, 5:40โฏPMApplicationsPoster presentation only
The Timepix4 provides time of arrival (ToA) and time over threshold (ToT) information on detected events, enabling sub-pixel position reconstruction beyond simple pixel-centre assignment [1]. We present an evaluation of centroiding methods for Timepix4 electron clusters, aimed at improving spatial resolution by combining the complementary information carried by ToT and ToA. Using Allpix2...
Go to contribution page -
Marie Andrae (Synchrotron SOLEIL)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
In recent years, significant efforts have been undertaken to extend the operational range of hybrid photon-counting detectors towards the tender and soft X-ray regime. In parallel with the development of new sensor technologies โ notably Low-Gain Avalanche Detectors (LGADs) and thin entrance windows (TEW) [1] โ these efforts have focused on the optimization of readout ASICs, with the...
Go to contribution page -
Miroslaw Zoladz7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
Charge sharing constitutes a fundamental limitation in hybrid pixel detectors operating in single-photon-counting mode. As the charge cloud generated by an absorbed X-ray photon drifts toward the collection electrodes, it undergoes lateral diffusion. When the interaction occurs in proximity to pixel boundaries, the deposited charge is distributed among adjacent pixels. Consequently, instead of...
Go to contribution page -
Theophile Chirac7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Microchannel plates (MCP) are a kind of electron multiplier widely used for intensifiers, sensitive detection and time gated 2D imaging apparatus. With coating strips used as a photocathode, they become a powerful tool for X-ray detection [1]. In the Laser Megajoule Facility, they are key components to notably X-ray framing cameras embed in several plasma diagnostics (imagers of spectrometers...
Go to contribution page -
Filippo Baruffaldi (Dectris AG)7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
This work presents the characterization of a full detector module based on the DECTRIS JUNGFRAU charge-integrating ASIC, developed to overcome the count-rate limitations of traditional counting detectors [1]. The module consists of 8 ASICs in a 512โ1024 active pixel array, bump-bonded to a monolithic 450 ยตm Si sensor, for an approximate sensitive area of 4โ8 cmยฒ. The Jungfrau ASIC features a...
Go to contribution page -
ไปปไฝณไน Jiayi REN7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
The China Spallation Neutron Source (CSNS) is undergoing an upgrade to CSNS-II, targeting an increase in the proton beam power to 500 kW. This upgrade introduces stringent requirements for neutron detector readout electronics, including operation under vacuum conditions, higher neutron flux, increased counting rates, improved spatial resolution, and reduced power consumption. Conventional...
Go to contribution page -
Andrea Sagatova (Institute of Nuclear and Physical Engineering, Slovak University of Technology, Ilkoviฤova 3, 841 04 Bratislava, Slovak Republic)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Timepix detectors have a great advantage in the capability of spectral particle track imaging in um scale, reflecting the pixel size. This requires precise per pixel energetic calibration. The Timepix detector energetic calibration is achieved usually by photons with energies up to 100keV that create a charge in a single pixel, so-called low-energy calibration. High-energy heavy charged...
Go to contribution page -
Jakub Miszczynski (AGH University of Krakow (PL))7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
This work presents a comparative study and optimization of a fast charge-sensitive amplifier (CSA) intended for hybrid pixel detectors operating in single-photon-counting (SPC) mode. The design objective is to minimize electronic noise while maximizing pulse-processing speed under stringent power constraints. Two advanced technology nodes are investigated: a 40 nm planar CMOS process and a 16...
Go to contribution page -
Alessandro Marras7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
The CoRDIA detector (Continuous Readout Digitising Imager Array) is an X-ray imager being developed for scientific experiments at diffraction-limited synchrotron rings.
Go to contribution page
It is designed to be capable of continuous operation at 150 kframe/s and features a compact pixel size (110x110 ฮผm^2), that includes digitisation and fast data streamout circuits within the pixel array, so that they do not... -
Stefano Capra (University of Milan, INFN (Milan))7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
The FAMU [1] experiment at RIKEN-RAL aims at a high-precision measurement of the hyperfine splitting of muonic hydrogen through the detection of an excess of characteristic X-rays emitted by muonic oxygen following laser-induced [2] excitation. The X-ray detection system is based on LaBr3:Ce scintillators read out by both photomultiplier tubes (PMTs) and SiPM arrays, requiring stable energy...
Go to contribution page -
Mostafa Mahmoud Cherif (Universitรฉ Paris-Saclay (FR))7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
With the High Luminosity LHC (HL-LHC) upgrade scheduled for 2030, a major upgrade of the LHCb experiment is planned to adapt to the harsh environment expected with the increased pile-up, as the number of interactions per bunch crossing will increase eight-fold. At the Upstream (UP) and MightyTracker tracking stations, Monolithic Active Pixel Sensors (MAPS) have been chosen for their high...
Go to contribution page -
Yoshiharu Kitayama (F-REI)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Portable 4ฯ gamma-ray imagers are promising tools for nuclear security, decommissioning, and contamination monitoring. However, existing gamma-ray imagers are generally expensive, which limits their use in applications involving multiple imagers. One major reason for the high cost is that conventional systems require from hundreds to tens of thousands of readout channels, as well as complex...
Go to contribution page -
S. Ikram (UCLouvain, Centre for Cosmology, Particle Physics and Phenomenology (CP3), Louvain-la-Neuve, Belgium)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation + pitch
To address the need for high-resolution muon imaging in environments with significant logistical constraints, we are developing a field-deployable detector system based on glass Resistive Plate Chambers (gRPCs). While RPCs are a mature and widely used technology, this work emphasizes the design of a gas-tight configuration suited for flexible muography applications. The system is conceived to...
Go to contribution page -
Dr Veta Ghenescu (Institute of Space Science subsidiary of INFLPR (RO))7/1/26, 5:40โฏPMApplicationsPoster presentation only
Highly compact and highly granular electromagnetic calorimeters are required for precision luminosity measurements at future eโบeโป colliders. Such detectors are also essential for determining the positron multiplicity and energy spectra in the LUXE experiment [1], which investigates strong-field QED through laserโelectron interactions.
Go to contribution page
In a luminometer, where Bhabha scattering serves as the... -
Stefano Capra (University of Milan, INFN (Milan))7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
High-purity germanium detectors play a key role in rare-event searches performed in underground laboratories, where ultra-low electronic noise is essential to achieve the required sensitivity. In this context, charge-sensitive preamplifiers rely on very high-value feedback resistances (โผ1 Gฮฉ), whose implementation poses significant challenges in terms of integration, stability, and noise...
Go to contribution page -
Mujin Li (IHEP)7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
SHINE (Shanghai HIgh repetitioN rate XFEL and Extreme light facility) is the first XFEL facility working in the hard X-ray region in China. To fulfill the special requirements of SHINE, a new pixel array detector, STARLIGHT (SemiconducTor Array detectoR with Large dynamIc ranGe and cHarge integrating readout), is being developed. HYLITE (High dYnamic range free electron Laser Imaging...
Go to contribution page -
Bohumir Zatko (Institute of Electrical Engineering, Slovak Academy of Sciences)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Silicon carbide (SiC) is a wide-bandgap semiconductor with significant potential for detecting various types of radiation. An additional advantage is the commercial availability of high-quality crystalline SiC materials necessary for the fabrication of radiation detectors. The 4H-SiC polytype is a good candidate because of a band gap energy of 3.23 eV at room temperature, a breakdown voltage...
Go to contribution page -
Dr Konstantinos Karafasoulis (Hellenic Army Academy)7/1/26, 5:40โฏPMImaging theoryPoster presentation only
Rapid and reliable localization of radioactive sources is a critical requirement in nuclear security, border protection, radiological emergency response, and the prevention of illicit trafficking of radioactive materials. In our previous work, we investigated radioactive source position estimation using a coded aperture device combined with machine learning, demonstrating the potential of...
Go to contribution page -
Sofia Mazzolani (University of Camerino & Istituto Nazionale di Fisica Nucleare)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Report of the performance of the singleโsided silicon microstrip detector (MSD) used in the magnetic spectrometer of the FOOT (FragmentatiOn Of Target) experiment โdevoted to fragmentation studies for hadrontherapy and space radiation protectionโ showing high (>95%) detection efficiency from recent beam tests at CNAO (National Center for Oncological Hadrontherapy, Pavia).
Go to contribution page -
Junjiang Liu (Tsinghua university)7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
The paper presents an electronic thinning method for hybrid pixel detectors(HPD) used in electron microscopy. Theoretically, the spatial resolution of a pixel detector improves with decreasing pixel pitch. However, as the pixel size diminishes, a single incident particle may induce signals across multiple adjacent pixels caused by scattering, the charge-sharing effect makes it difficult to...
Go to contribution page -
Mr Tomonao Inoue (Rigaku Corporation)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Recent advancements in X-ray sources and experimental techniques have increased the demand for area detectors capable of covering a wide X-ray energy range, including the soft and tender X-ray regime, while supporting efficient data acquisition. In particular, low-energy X-ray measurements impose stringent requirements on detector noise performance, stability, and vacuum compatibility.
Go to contribution page
In... -
Jonathan Mulvey (Paul Scherrer Insitute)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
The newly upgraded Swiss Light Source (SLS) 2.0, a fourth-generation synchrotron, has begun
Go to contribution page
operation. Photons with energies up to 80 keV will be available at increased flux compared to the
third-generation source it replaces. In particular, the brilliance is expected to increase by two orders of
magnitude. In this energy range, silicon is no longer an efficient detection material.... -
Dr Youngseok Lee (Korea Institute of Fusion Energy (KFE))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Diamond-based detectors have gained significant attention in fusion neutron diagnostics owing to their outstanding radiation hardness, sub-nanosecond timing response, and capability for energy-resolved measurements [1,2]. In this study, neutron spectrometry experiments were conducted at the KSTAR tokamak using two geometrically distinct single-crystal diamond detector systems. Time-resolved...
Go to contribution page -
Yohan Shin (Inje University, College of Medicine)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
- Purpose
Lead halide perovskites (such as CsPbXโ) have been highly spotlighted in the field of solar cells due to their outstanding optoelectronic properties, including excellent charge-carrier mobility and high stopping power.[1] Recently, leveraging these exceptional radiation-responsive characteristics, they have begun to be investigated as novel real-time dosimetric materials in the...
Go to contribution page -
Hannah Patz (University of Florida)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Particle discrimination is a valuable imaging detector capability for applications such as medical physics, environmental monitoring, decontamination, and nuclear forensics. Across these areas, samples can have complex matrices, and a large range of radioactivity levels, which present analysis and measurement challenges for digital autoradiography systems (e.g., knowing how long to measure and...
Go to contribution page -
Dr Bo Kyung Cha (KERI)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Digital flat-panel detectors based on the indirect detection scheme commonly employ amorphous silicon TFT or silicon CMOS matrix arrays combined with a variety of scintillators and they are widely used in medical imaging, security screening, and nondestructive testing. Scintillators are essential components in indirect X-ray detectors, as they convert high-energy ionizing radiation, such as...
Go to contribution page -
Jiho Lee (Department of Foundry Engineering, Dankook University)7/1/26, 5:40โฏPM1Sensor Materials, Device Processing & TechnologiesPoster presentation only
Junmo Yang1, Jiho Lee1, Jibum Kim1, Jungwon Kang1,2*
1. Department of Foundry Engineering, Dankook University, Yongin-Si, 16890, Gyeonggi-Do, Republic of Korea
2. Department of Semiconductor Convergence Engineering, Dankook University, Yongin-Si, 16890, Gyeonggi-Do, Republic of Korea
* Corresponding author: jkang@dankook.ac.krThis study...
Go to contribution page -
Saverio Silletta (PSI)7/1/26, 5:40โฏPM1ApplicationsPoster presentation + pitch
Resonant inelastic X-ray scattering (RIXS) imaging directly combines spatial and spectral information by targeting specific atoms within complex structures while remaining sensitive to multiple excitations simultaneously. To effectively measure the scattering spectra of many interesting materials a high spatial resolution in one dimension in the soft X-ray regime (<3 keV) on the detector is...
Go to contribution page -
Robert Astalos (Comenius University (SK))7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
The Tile Calorimeter (TileCal) is a sampling hadronic calorimeter covering the central region of the ATLAS experiment at the CERN Large Hadron Collider (LHC). It employs steel as the absorber material and plastic scintillators as the active medium. The High-Luminosity LHC (HL-LHC), scheduled to start operation in 2030, will deliver instantaneous luminosities significantly exceeding the...
Go to contribution page -
Matej Baluลกรญk (Institute of Nuclear and Physical Engineering, Slovak University of Technology in Bratislava)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Low energy neutron spectrometry with Timepix3 SiC detectors
Silicon carbide (SiC) is attracting increasing interest as a sensor material due to recent advances in crystal growth technology and its substantial advantages over silicon, including a wide band gap and a high critical electric field for specific applications. In addition, its high displacement energy makes SiC particularly...
Go to contribution page -
Dr Bo Kyung Cha (KERI)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
X-ray detection plays a crucial role in medical imaging, industrial inspection, and security. At present, X-ray detectors are typically categorized into two types: direct conversion and indirect conversion methods. Semiconductor-based direct radiation detection, utilizing materials such as CdZnTe, CdTe, GaAs and metal halide perovskites, has rapidly advanced and demonstrated diverse...
Go to contribution page -
Erik Frรถjdh (Paul Scherrer Institute)7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
Single photon counting detectors revolutionized data acquisition at synchrotrons when they were introduced in the mid-2000s and quickly became ubiquitous at beamlines. We believe they will continue to play an important role for diffraction-limited light sources, even as the increased flux makes counting more challenging due to pulse pile-up in the analog front end.
Matterhorn is a new...
Go to contribution page -
Tae Min Hong (University of Pittsburgh (US))7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
We present an implementation of edge AI to compress data on an in-memory analog content-addressable memory (ACAM) device. A variational autoencoder is trained on a simulated sample of energy measurements from incident high-energy electrons on a generic three-layer scintillator-based calorimeter. The encoding part is distilled into tabular format by regressing the latent space variables using...
Go to contribution page -
Ashish Bisht (Fondazione Bruno Kessler (FBK))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Low-Gain Avalanche Diodes (LGADs) are typically fabricated on p-type substrates, following an nโp$^+$โp junction configuration, where a boron-doped layer forms the gain region.
This architecture is considered optimal for timing and particle-tracking applications since the primary charge carriers initiating the avalanche process are electrons, which feature higher drift velocity and...
Go to contribution page -
Julian Weick (CERN)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
The increasing integration density of silicon pixel sensors, together with emerging applications such as module-level power conversion and enhanced on-detector signal processing, significantly raises the demand for advanced thermal management solutions. Efficient heat removal at the module level is becoming a critical requirement for ensuring stable and reliable operation. In this work, we...
Go to contribution page -
Mr YOUNGHWAN LIM7/1/26, 5:40โฏPMImaging theoryPoster presentation only
Digital tomosynthesis (DTS) is a limited-angle imaging technique that provides volumetric information at a fraction of computed tomography (CT) dose [1]. However, the restricted angular coverage inherently produces out-of-plane artifacts, degrading slice selectivity and contrast-to-noise ratio (CNR). Slice-thickness filtering (STF) applied after filtered back projection (FBP) reconstruction is...
Go to contribution page -
Mr DAICHI SATO (National Institute of Technology (KOSEN), Toyama College)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Photon-counting computed tomography (PCCT) has attracted considerable interest as a next-generation medical X-ray imaging modality because of its high spatial resolution, intrinsic spectral sensitivity, and improved dose efficiency [1]. While current commercial PCCT systems mainly employ direct-conversion semiconductor detectors, indirect photon-counting detectors based on scintillators and...
Go to contribution page -
Fengwangdong Zhang (Universite Libre de Bruxelles (BE))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Compared with the current LHC CMS tracker, the new CMS tracker of the High-Luminosity LHC is undergoing significant enhancements, including the development of a new silicon detector system with improved radiation hardness, higher granularity, and extended coverage up to a pseudorapidity of |ฮท|โผ4. In addition, the outer tracker (OT) will be equipped with two types of pT modules (2S and PS) that...
Go to contribution page -
Alhanouf Alrwais (1. Department of Materials, University of Manchester, Manchester, United Kingdom 2. Nuclear Technologies Institute, King Abdulaziz City for Science and Technology (KACST), Riyadh 11442, Saudi Arabia)7/1/26, 5:40โฏPMImaging theoryPoster presentation only
Spectral performance in hyperspectral X-ray imaging using the HEXITEC 6ร2 detector system is optimised through systematic parameter tuning and spectral data processing. The approach aims to improve energy-resolved imaging and enhance the quality of spectral information.
Data acquisition and processing are carried out using the Odin software framework, with particular attention to parameters...
Go to contribution page -
Esteban Curras Rivera (EPFL - Ecole Polytechnique Federale Lausanne (CH))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
A new concept of tracking detector based on Scintillating Fibres (SciFi) read out with multichannel silicon photomultipliers (SiPMs) was installed during the upgrade I of the LHCb experiment at CERN. One of the main challenges that the SciFi tracker will face during its operation is the high radiation environment due to fast neutrons. In view of LHCb Upgrade II in 2033, the radiation levels...
Go to contribution page -
Chenzhuo Chang (IHEP)7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
HEPS (High Energy Photon Source) is the first fourth-generation light source in China, featuring high-energy, high-luminosity X-rays. Since more than half of its end stations generate photon energies above 25 keV, high-Z detectors are essential. Additionally, advanced experiments such as X-ray Photon Correlation Spectroscopy (XPCS) and ultrafast dynamics studies necessitate detectors with high...
Go to contribution page -
Weigang Yin7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
The China Spallation Neutron Source (CSNS) is currently upgrading to CSNS-II, increasing the proton beam power to 500 kW and constructing several new neutron spectrometers. The CSNS-II upgrade poses significant challenges for detector and electronics systems, including higher counting rate, improved position resolution requirement, and vacuum operating environment. In this paper, we present an...
Go to contribution page -
Marta Baselga (Technische Universitaet Dortmund (DE))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Diamond detectors have been studied since long, its radiation hardness makes it appealing for beam monitoring application and its tissue equivalence makes it attractive for radiotherapy or dosimetry. Its low leakage current allows to operate diamond detectors without doping.
Single crystal diamond is vastly used, but to approach a most cost effective material, here a polycrystalline diamond...
Go to contribution page -
Dr Sonia Fernandez-Perez (DECTRIS)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Over the last two decades, Hybrid Photon-Counting (HPC) pixel detectors have revolutionised and enabled a wide range of techniques at synchrotron light sources. These achievements are driven by their high frame rates, large dynamic range, radiation hardness, high DQE, and no noise associated with the readout operation [1]. However, the impact of HPC detectors has so far been largely confined...
Go to contribution page -
Sunghoon Choi (Electronics and Telecommunications Research Institute (ETRI))7/1/26, 5:40โฏPMImaging theoryPoster presentation only
Speckle-based X-ray dark-field imaging is attractive because it can deliver small-angle scattering contrast with a comparatively simple optical setup, but quantitative modeling of weakly absorbing microstructures in hydrated environments still requires improved treatment of multiple refraction and unresolved ultra-small-angle X-ray scattering (USAXS). Building on the wave-optics simulation...
Go to contribution page -
379. R&D and performance studies of improved RPC detectors for the CMS muon system upgrade at HL-LHCGiulia Giannandrea (Pavia University and INFN (IT))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in particle physics, for example, in the muon system of the CMS detector at the CERN Large Hadron Collider (LHC), as they provide fast timing information for efficient muon triggering. In view of the upcoming High-Luminosity (HL) LHC phase, an improved RPC detector (iRPC) has been developed to cope with the significantly higher...
Go to contribution page -
Prof. Gordana Lastovicka Medin (University of Montenegro (ME))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
This work investigates the impact of irradiation on the timing performance of 3D silicon devices and electric field and charge collection uniformity. The study is organized in two parts. First, the response of irradiated and non-irradiated double-sided 3D CNM devices is compared. Second, the performance of a 3D IMECAS device is analyzed when un-irradiated and irradiated; this device...
Go to contribution page -
Donya ahmadi (Vrije Universiteit Brussel (BE))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Gaseous detectors play a crucial role in high energy physics experiments, yet their operation often relies on fluorinated gases with a very high Global Warming Potential (GWP). Resistive Plate Chambers (RPCs) operated in avalanche mode typically use high performance gas mixtures based on high-GWP F-gases such as CโHโFโ and SFโ.
Go to contribution page
As environmental concerns grow and regulations become... -
Mr Ritesh Verma (IIT Bombay)7/1/26, 5:40โฏPMImaging theoryPoster presentation only
Photon scatter remains a major source of image degradation in Single Photon Emission Computed Tomography (SPECT), leading to reduced contrast recovery and quantitative accuracy. Conventional reconstruction frameworks typically reject these scattered events. This study investigates the utility of rejected scattered data as a "scatter-informed" initial estimate for Maximum Likelihood Expectation...
Go to contribution page -
Afonso Correia (University of Aveiro)7/1/26, 5:40โฏPMImaging theoryPoster presentation only
Anger Cameras have been widely used in nuclear medicine, presenting, however, limitations in detection efficiency for higher photon energies and sensitivity due to the presence of a lead collimator. Compton Cameras (CC) are potential competitors, primarily because they improve sensitivity in imaging radioactive sources by eliminating the mechanical collimator. In a CC, physical collimation is...
Go to contribution page -
Katarรญna Foss (Institute of Nuclear and Physical Engineering, Slovak University of Technology, Ilkoviฤova 3, 841 04 Bratislava, Slovakia)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Silicon carbide provides significant advantages as a radiation sensor, such as high radiation hardness and wide temperature operation, suitable for application in nuclear energy, accelerator physics research, particle therapy and outer space. Combined with the high spatial segmentation of pixel imagers and noiseless counting response of Timepix chip [1], high-resolution radiation measurement...
Go to contribution page -
Jibum Kim (Department of Foundry Engineering, Dankook University)7/1/26, 5:40โฏPM1Sensor Materials, Device Processing & TechnologiesPoster presentation only
Chanwoo Doo1, Jibum Kim1, Jiho Lee1, Jungwon Kang1, 2, *
Go to contribution page
1. Department of Foundry Engineering, Dankook University, Yongin-Si, 16890, Gyeonggi-Do, Republic of Korea
2. Department of Semiconductor Convergence Engineering, Dankook University, Yongin-Si, 16890, Gyeonggi-Do, Republic of Korea
* Corresponding author:... -
Nikola Kurucovรก (Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Timepix3 hybrid pixel detectors [1] are widely used in applications requiring precise radiation spectrometry, including space instrumentation [2], high-energy and nuclear physics [3] or neutron detection [4, 5], where detectors are frequently exposed to varying thermal conditions. Temperature fluctuations can influence the spectrometric response, affecting both the accuracy of energy...
Go to contribution page -
Ms Bhakti Kanulal Chitroda (University of New Mexico (US))7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
The ATLAS experiment inner detector will undergo a complete replacement with the all-silicon Inner Tracker (ITk) during the 2027โ2029 shutdown, in preparation for operation at the High-Luminosity Large Hadron Collider. The ITk pixel detector, forming the innermost tracking system, is designed to operate under unprecedented radiation levels and particle densities. Its innermost layer (Layer 0)...
Go to contribution page -
Davide Cristoforetti7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
The High Luminosity upgrade of the Large Hadron Collider at CERN (HL-LHC) will provide unprecedented instantaneous and integrated luminosities of around 5 x 10$^{34}$ cm$^{-2}$ s$^{-1}$ and 3000/fb, respectively. The expected average of 140 to 200 collisions per bunch-crossing (pileup) represents a severe challenge for the detectors. The endcap part of the CMS calorimeters will be replaced by...
Go to contribution page -
Michele Cascella7/1/26, 5:40โฏPMFront end electronics and readoutPoster presentation only
The MAX IV Synchrotron facility in Lund, Sweden, employs more than 30 X-ray detectors and cameras for the operation of its beamlines.
The most common drivers for the choice of a certain technology are the spatial and temporal resolution, and the energy range. Different detector typologies (imaging, energy sensitive...) and technologies (photon counting, charge integrating...) respond to...
Go to contribution page -
Debora Magalhaes Suarez (DESY)7/1/26, 5:40โฏPMSensor Materials, Device Processing & TechnologiesPoster presentation only
Two pad sensors of high-flux CdZnTe grown by Redlen Technologies with different anode metallization (platinum and titanium-gold) were characterized under direct X-ray beam in P07 beamline at Petra III, during 40-bunch mode operation. A Transient Current Technique (TCT) readout setup from the University of Hamburg [1] was used, with a homemade Bias-T, a Femto 40 dB 2GHz amplifier and a...
Go to contribution page -
Karam Kaspar (Ghent University (BE))7/1/26, 6:00โฏPMApplicationsPoster presentation only
The High-Luminosity LHC upgrade will require detector systems capable of operating in unprecedented particle rates and radiation environments. To meet these challenges and maintain efficient muon triggering and reconstruction, new Gas Electron Multiplier (GEM) ME0 detectors will be installed in the forward region of the CMS experiment, complementing the already installed GE1/1 GEM detectors...
Go to contribution page
Choose timezone
Your profile timezone: