Summary of RPC interventions in the cavern on 12/11 [e-log]
The following gaps, drawing high current, were disconnected on the chamber side:
- BML2C09.PI.DP2.Ly0.DZ2
- SPC4C10.CO.DP1.Ly0.DZ1
- BMF3A12.CO.Ly1.DZ1
BMS.C.10.CO.Ly0 HV channel [e-log]
- The HV channel ramped down due to HvGapSafety for SPC4C10.CO.DP2.Ly0.DZ1 gas gap that was driving high current at 15:44 (20.42 uA 8514V). SPC4C10.CO.DP2.Ly0.DZ1 gas gap masked and HV channel brought back to READY (9000V).
Current of the gas gap to be monitored. Gas gap to be disconnected in the next cavern intervention.
- High rate of s17_t4 trigger tower (1.2kHz instead of ~1Hz). BMS5C10.PI.Ly0.ETA Vth lowered from 0.7 to 0.3 [e-log].
BMS.A.16.CO.Ly1 HV channel [e-log]
- The RPC HV channel BMS.A.16.CO.Ly1 ramped down, giving NOT_READY for RPC, due to SPC4A16.CO.DP1.Ly1.DZ1 driving high current (60uA at 9056V).
Already at 5000V, the SPC gas gap drives high current (32uA).
HV channel masked. Gas gap to be disconnected.