Meeting Details
Agenda Items and Notes
1. Discussion on the process of linking the electromagnetic simulation data to ANSYS
- Linking data from NIQS to ANSYS works
- One timestamp of one measurement file tested
- Boundary conditions seem fine
- Stresses in the order of GPa observed
- Now:
- Investigate on ramping scheme and time constant reduction
News on 77K setup
- Current injection burned through where it was isolated by plastic guides
- Now:
- 200 um tape (soldered) instead of 70 um
- Adjustments to holder and tape guides for better thermal exchange/nitrogen access
Compression test simulation
- 2D and 3D models validated
- 10% error between 2D and 3D models
- 1.8x-2x mismatch to measurement data
- Now:
- Mesh matching for better contact surfaces in 3D
Next Meeting