• NICQS load inputs implementation into ANSYS is running
  • Simulations with 1 kA current and a 20 T background field indicate a hub stress of approximately 3 GPa, exceeding acceptable limits
    • Reduce current density by adapting the coil design
    • Design a special coil configuration, including co-winding HTS tape with Hastelloy tape
    • Decrease the time constant of the coil
    • Operate the coil at lower current
    • Apply slower ramping of the external magnetic field
  • Update mechanical simulations accordingly
  • Simulation including cooldown