MCBXFA5 - does it make sense to test to higher current?

→ Europe/Zurich
Zoom Meeting ID
69676874207
Host
Susana Izquierdo Bermudez
Useful links
Join via phone
Zoom URL

Main parameters (2D computations):

Inom 1593 A
Bp at Inom 3 T
Mid-plane stress at Inom 84 MPa
I/Iss (1.9 K) 0.42  
Iss (1.9 K) 3793 A
I/Iss (4.5 K) 0.58  
Iss (4.5 K) 2747 A

 

Going above 2 kA needs to be carefully verified, 2 kA is about 70 % of short sample...so not so interesing (paramters simple scaling, CIEMAT to provide the good numbers)

I, A 2000 2500
I/Iss (4.5 K) 73 91
Mid plane stress 132 207
Bp, T 3.8 4.7

 

Other limitations to keep in mind:

  • Max Vdump = 500 V (above that we are taking a bit of risk, for 2.5 kA current this is 0.2 mOhms (nominal is 0.15 mOhms), according to Franco no problem
  • SM18 uses the 2 kA power convertor, but Franco does not see any particular problem on using the big power convertor, they use it with other small magnets operating at 2-3 kA

 

For second season of the discussion

  • CIEMAT to verify load line, including 3 D effects
  • Asses if 2.5 kA can be considered a safe current or we are taking any risk. We don't want any risk!

 

Susana

 

There are minutes attached to this event. Show them.
    • 09:00 → 09:20
      MCBXFA5 - does it make sense to test to higher current? 20m
      Speaker: Fernando Toral (CIEMAT - Centro de Investigaciones Energéticas Medioambientales y Tec. (ES))