Performance study for the CEPC ScW Ecal (12' + 3')

4 Aug 2016, 12:15
15m
Chicago 8

Chicago 8

Oral Presentation Detector: R&D and Performance Detector: R&D and Performance

Speaker

Dr Zhigang Wang (IHEP,China)

Description

This article presents the status of a highly granular scintillator-based electromagnetic calorimeter (ScW Ecal) proposed to realize Particle Flow Algorithm for the CEPC. The ScW Ecal is a sandwich calorimeter consists of sampling and sensitive layers. The material of tungsten is selected as absorb material. The active layers are plastic scintillators consisting of 5×45 mm2 scintillator strips. The scintillator strips in adjacent layers are perpendicular to each other to achieve a 5×5 mm2 effective transverse size. Each strip is covered by a reflector film to increase collection efficiency and improve uniformity of the scintillation light. Photons from each scintillator strip are read out by very compact photon sensor, SiPM, attached at the end of the strip. Scintillator-SiPM unit is the core part of ScW Ecal. Optimization of the scintillator-SiPM unit such as shape of scintillator strip, thickness of scintillator strip, design of combination of a scintillator and a SiPM are discussed. Additionally, the performance of SiPM was tested. The gain is typically of order a few 105, the dark noise rate and the inter-pixel cross-talk probability are of order 100 kHz/mm2 and 0.1 respectively. The SiPM dynamic range is determined by the number of pixels.