Experimental Study on Reverse Recovery Characteristics of High Power Thyristors in HVDC converter valve

7 Jul 2016, 13:30
1h 30m
Twin Peaks (Palace Hotel San Francisco)

Twin Peaks

Palace Hotel San Francisco

Poster Presentation Power Electronics, Power Supplies, Prime Power, Rotating Machines, and Energy Converters Poster 2-A

Speaker

Ms Ke Yue (State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, Shaanxi Province, China)

Description

The high power thyristor is the basic unit in HVDC converter valve, and its transient performance has a tremendous influence on the reliability, stability of the whole power system and designs of thyristor control unit. For this reason, each thyristor needs to be tested routinely before the operation of the power system. However, there is no specification for the routine test of thyristor valve. The test methods of thyristors are associated with the relationship between reverse recovery characteristics and external operating conditions. Therefore, to provide a reference and basic datum for the routine test of thyristor valve, it's necessary to investigate the reverse recovery characteristics of high power thyristor in converter valve. In this paper, we focus on the evaluation of thyristor reverse recovery time by forward current, namely forward current amplitude, conduction pulse width and rate of change of commutating current. The influences of thyristor reverse recovery time have been investigated to determine the parameters of thyristor testing based on testing the reverse recovery process of thyristor and analyzing the influence mechanisms. The results show that the reverse recovery time mainly depends on peak forward current and commutating di/dt, where reverse recovery time decreases with the increase of the commutating di/dt and is directly proportional to peak forward current; the commutating di/dt relative to peak forward current is the main influence factor of reverse recovery time; the ration of turn off time and reverse recovery time is less than 1.2, which is particularly significant for the evaluation of thyristor reverse recovery ability by impulse test in thyristor testing.

Primary author

Ms Ke Yue (State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, Shaanxi Province, China)

Co-authors

Can Guo (Xi'an Jiaotong University) Mr Dezhi Kong (State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an, China, 710049) Dr Lei Pang (State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, Shaanxi Province, China) Dr Longchen Liu (State Grid Sichuan Electric Power Research Institute, Chengdu, China, 610072) Prof. Qiaogen Zhang (State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, Shaanxi Province, China) Mr Shaobin Li (State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, Shaanxi Province, China) Tonglei Wang (Xi'an Jiaotong University)

Presentation materials

There are no materials yet.

Peer reviewing

Paper

Paper files: