5–9 Jul 2016
<a href=http://www.sfpalace.com/>Palace Hotel San Francisco</a>
America/Los_Angeles timezone

Multi-Parameter Analysis in Single-cell Electroporation Based on the Finite Element Model

7 Jul 2016, 13:30
1h 30m
Twin Peaks (Palace Hotel San Francisco)

Twin Peaks

Palace Hotel San Francisco

Poster Presentation Biological, Medical, and Environmental Applications of Power Modulators Poster 2-A

Speakers

Dr Chenguo Yao (Chongqing University)Ms Hongmei Liu (Chongqing University)

Description

Pulsed electric fields have recently been the focus of considerable attention because of their potential application in biomedicine. However, their practical clinical applications are limited by poor understanding of the interaction mechanism between pulsed electric fields and cells, particularly in different effect of electroporation exposed in different parameters, and the optimal pulsed parameter is still vague. A multi-shelled dielectric model considering the inner membrane was established by the finite element software COMSOL in this paper. Different shock protocols (different pulsed duration/strength/frequency/polarity) was exposed to the cell model respectively to simulate and analyze the influence of pulse parameters on varying degrees of electroporation by comparing the dynamic development of the pore radius and electroporation region (include the distribution of recoverable, non-recoverable, and non-electroporation areas on the cell). Results showed that the conventional pulses have better efficiency in electroporation than high frequency pulses; The monopolar pulses with cumulative effect have much better electroporation effect than the bipolar pulses which have weakening effect when duration of single pulse reduced to nanosecond; and electric field strength was the major factor that induced electroporation, particularly in the recoverable pore, but it had minimal effect on pore expansion. However, pulse duration affects the non-recoverable pore, such that the high-intensity wide pulse is more useful in the field of irreversible electroporation. The high-intensity short pulse can increase permeability and maintain cell viability. This work done by this paper maybe exploited further to investigate the behavior of more complicated cell systems and to promote the optimized application of pulsed electric fields in clinical.

Primary author

Ms Hongmei Liu (Chongqing University)

Co-authors

Dr Chenguo Yao (Chongqing University) Dr Chengxiang Li (Chongqing University) Mr Shoulong Dong (Chongqing University) Mr Yajun Zhao (Chongqing University) Dr Yan Mi (Chongqing University) Mr Yanpeng Lv (Chongqing University)

Presentation materials

There are no materials yet.

Peer reviewing

Paper