18–22 Jun 2017
Hilton Brighton Metropole Hotel
Europe/London timezone

Signals from Cygnus

20 Jun 2017, 13:30
1h 30m
Hall 4 / Cambridge (Hilton Brighton Metropole Hotel)

Hall 4 / Cambridge

Hilton Brighton Metropole Hotel

Board: 11
Poster Particle Beam and Accelerator Technologies Poster session II - Particle Beam and Accelerator Technologies

Speaker

Mr Hoai-Tam Truong (National Security Technologies, LLC)

Description

*NSTec product number: DOE/NV/25946--3117

After the 1992 moratorium on underground nuclear testing, the Subcritical Experiment (SCE) program was initiated to support stockpile stewardship. The SCE laboratory is located in a tunnel complex 1,000 feet below ground surface at the Nevada National Security Site (NNSS). Cygnus is a radiographic x-ray source which is a primary diagnostic for the SCE program. The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources, Cygnus 1 and Cygnus 2. From end to end, the Cygnus machines utilize the following components: oil-filled Marx generator, water-filled pulse-forming line (PFL), water-filled coaxial transmission line (CTL), three-cell vacuum induction voltage adder (IVA), and rod-pinch diode. The diode pulse has the following electrical specifications: 2.25 MV, 60 kA, 60 ns. Each source has the following X-ray specifications: 1-mm diameter, 4 rad at 1 m, 50 ns. SCE shots are both single-event and high-value, therefore reliability and reproducibility are key issues of Cygnus. Prior to a SCE, there are a series of test shots performed for confirmation of high levels of reliability and reproducibility. For every shot on Cygnus, voltages and currents along the machine are recorded and monitored. In this paper we present extensive analysis of electrical waveforms which includes examination of multiple parameters (e.g. amplitude, pulse width, pulse shape). The results will involve a statistically meaningful shot sample where machine setup parameters are held consistent. A computer application will be developed for automated shot analysis. Correlation between waveform characteristics and dose performance will be established. This type of extensive, automated analysis will contribute to optimized Cygnus performance on SCEs.

*This work was done by National Security Technologies, LLC, under Contract No. DE-AC52-06NA25946 with the U.S. Department of Energy.

Primary author

Mr Hoai-Tam Truong (National Security Technologies, LLC)

Co-authors

Mr Michael Garcia (Sandia National Laboratories) Mr Keith Hogge (National Security Technologies, LLC) Mr Steven Huber (National Security Technologies, LLC) Mr Michael Misch (National Security Technologies, LLC) Mr Eugene Ormond (Sandia National Laboratories) Mr Jesus Perez (National Security Technologies, LLC) Mr Thomas Romero (National Security Technologies, LLC) Dr John Smith (Los Alamos National Laboratory)

Presentation materials

There are no materials yet.