Follow up from last meeting

The updated version of the proton parameter table attached to the indico page of the last meeting was discussed. A remark that the longitudinal emittance calculated after filamentation at SPS injection assume 4 MV in the 200 MHz and 0.4 MV in the 800 MHz cavities. An additional remark about potential well distortion will also be included at the bottom of the table.

Update on SPS coupled bunch instabilities - Simulation studies

Joel presented the status of the simulation studies on the SPS longitudinal coupled bunch instabilities in view of the LIU goal of reaching 2.4e11 p/b before scraping. The main contributions to the SPS longitudinal impedance model used for these studies are the 200 MHz and 800 MHz cavities, the kickers (mostly MKP), and the vacuum flanges. The effect of the feed-forward and the one turn delay feedback in the machine is taken into account by a reduction of the main harmonic of the 200 MHz cavity impedance (26 db for the LIU scenario). The studies concentrated on the following points: