Copper cables:

- Association of HV cables/connectors corrected in Excel file (ALICE TC to return HV cable which is now obsolete)

- FIT_A T0+ cables will be routed along the L3 ventilation pipe in order to be as short as possible

- ALICE TC to buy all FIT cables & connectors

- EN-EA to buy SMA Amphenol connectors

- EN-EA to fabricate FIT_A & V0+ PP1, PP0 and FIT_C; ALICE TC to provide geometric constraints/envelope

- EN-EA to install laser calibration patch-cords; FIT team to procure fibers and protection tubes

- FIT to provide labels for all cables & fibers

 

Optical fibers:

- FIT confirms that numbers provided by Giuseppe are fine, except the fanout which must be of 1m