Weekly summary and plan for the next week :

Problems with DIP values - SOLVED for the moment.
sTGC request : alarm on CO2 flow - DONE

 ------------------------

ALICE arrived with 3 x 2 chambers,
Friday, Saturday, Monday  :   8h30 Measurement with att. 1 then 1h access (9h30-10h30)
Tuesday : 8h30-9h30 att.1 for 1h, otherwise 2.2 in upstream field (not needed this week)
                (this week in the afternoon due to ATL-MM 13h-15h)
Will continue until Mid-February.

sTGC with one electronic test chamber - 1 month test, running
              3 x 4h filter scan  (range 100-1) upstream Today after ATLAS-MM / Sunday afternoon / Tuesday afternoon
sTGC Productiuon : 2 chambers QS2 production chamber in upstream position to be remmoved
                                  return beginning of March

ATLAS-MM :   MM SM2 detector in the bunker since today Wednesday
                          upstream scan at 9:30AM [Thursday].
                          ==> 20 min at each filter and in between a 46000 attenuation [333] for 5 minutes
                          50 / 20 / 10 / 6.9 / 4.6 / 2.1 / 1.5   - should be finished @2pm latest.
                          access after scan to move chamber.

CMS-RPC : installation of electronics for EcoGas, installation of 3 chambers in Trolley 3.
                    Currently using the default gas mixture for 1-2 weeks.


CMS-RPC trolly 1&3 


EP-DT2  & CMS-RPC :

       for the next days - repeatedly : 2h measurement with att. 100, then 2h no measurement (until 18 h)
        will continue with different att factors for the next 2 weeks.

LHCb +  
CMS-CSC small prototype  will move in 1-2 weeks back to downstream

CMS-GEM 1&2


EP-DT1

ATLAS-RPC - 2 setups, IMPACT now available.
         next 6 weeks :  Wednesday 3 short accesses with after Source ON within 3h - after access day.


CMS-DT MB 1&2 - to stopped on 30.01 with 1/15 irradiation.

        3 h  filter scan downstream (15 to higher) - to be checked with upstream stable filter scans.         

CMS-CSC + LHCb  : starting next week regular Thursday filter scans downstream 6.9, typically 10-18h.

EN-CV and ATLAS-NSW  samples installed on CMS-GEM (passive irradiation)
We will check for shadowing next week.