BI Signals to record and log
Giulia, Edgar, Richard, Romain, Jean, Michele, Athanasios, Federico
________________________________________
BPM
Agreed on that func specs are: Beam phase measurement w.r.t. RFQ phase
Then we all agree with Michele's assessment on that
• there is no need for a full standard BPM DAQ and related cables.
• a 'simple' front end analogue board (filtering + amp) could be needed
• the measurement can be done via a scope-based DAQ + scripts to tag and log data
Few options for read out:
• standard scope with his display and OS --> ethernet control and readout
• Picoscope-like DAQ (no monitor) --> Ethernet --> remote control and readout
• OASIS : in place at test stand for source, to be checked if spare channels available
Richard will check if spare channels are available at the test stand.
In general: wanting to sample RFQ freq 352MHZ we need ~1GS/s unless we do downsampling (as in LN4 BPMs) and few 100MS/s should be enough
________________________________________
BCT (3 units)
• DAQ will be based on standard TRIC card, acquisition via FESA and Expert GUI.
• Everything can be logged in NXCALS, including traces
• my offline thought/reminder:
o being fully integrated in FESA one can access via PyJapc, for example inside EM scripts to automatically normalize emittance measurements for intensity if needed)
• Romain proposes to install legacy head amplifier (already integrated on BCT) + upgraded (Marek's) head amplifier, to be integrated on the girder
o Romain will contact Benoit R.
• ABP Baseline is that OASIS is NOT needed for BCTs
________________________________________
Slit-Grid emittance meter
• SLIT cooling:
o with accurate thermo-mechanical simulations pending (we'll go as far as possible anyway) we agreed on that baseline == implement slit water cooling
o Jean is contacting Benoit R. for integration of cooling components and we will see with CV to ensure-setup proper water flow
• Slits: will be driven by standard VME stepping motor ( FESA = BStepMotorVME)
• Grids == standard LN4 FESA classes (BOSEMCTRL + BEMCPS) , driven by standard VME stepping motors (FESA = BStepMotorVME)
• ABP baseline == use python scripts to make slit-grid an emittance meter
o Giulia to verify resources with Alessandra
o Federico to provide support
________________________________________
Spectrometer SEM grid
• 48 channels standard IN-OUT grid (only H plane)
• will need to ask JFC to deploy OP GUI for this device
• can be logged on NXCALS
________________________________________
Schedule:
• be ready with all HW necessary to close vacuum on May 1st 2022
• be ready with all DAQ for starting dry runs on Oct 1st 2022
________________________________________
Conclusions for today:
• most urgent is to give MME all necessary input for integration (including Slit cooling, EM grids pre-amp boxes, BCT head amps)
• provide DICs and racks requests to Edgar + Karl Schirm by Nov 15th