Annealing effects in n+p strip detectors irradiated with high neutron fluences

18 Nov 2010, 09:00
20m
503/1-001 - Council Chamber (CERN)

503/1-001 - Council Chamber

CERN

162
Show room on map

Speaker

Igor Mandic (University of Ljubljana)

Description

Miniature p-type strip detectors were irradiated with reactor neutrons to fluences in the range from 2e14 neq/cm2 to 5e15 neq/cm2. Collected charge was measured with signals caused by fast electrons from Sr90 source and read out by SCT128A chip. Collected charge and leakage current was measured up to high bias voltages (1400 V) at which signs of charge multiplication can be observed. Detectors were submitted to successive annealing steps at 60°C up to total time of 5040 minutes. Increase of collected charge after long annealing times was measured at high bias voltages. A similar effect was observed in the leakage current, which at high voltages increased with reverse-annealing time.