E. Balci, M. Gonzalez Berges, S. Jackson, M. Gasior, M. Dolenc, D. Alves
Capture (mostly used by the OMC team)
Sw trigger
Working? Yes
Hw trigger
Working? Yes
There was a problem with the buffering mechanism
Manuel fixed it in the development version but the problem still exists in the deployed version
Update [11/07/2024]: still the case
Update [10/10/2024]: version with the fix was used during an MD but not left running operationaly - part of a broader set of changes. AGREED TO DEPLOY OPERATIONALLY DURING EYETS'24/25 only on std BPMs
Update [10/10/2024]: Manuel reported observation that some DOROS boxes can only be triggered once. When triggered a 2nd time it doesn't work and require a sw reset [UDP flags disappearing?]. Can be reproduced in the lab - to be investigated between Manuel and Miha
Freeze (linked to "PM on-demand" functionality)
Sw trigger
Working? Yes
Hw (BST) trigger
Working?
Update [11/07/2024]: Manuel and Miha and Marek agreed that the BST capture and freeze are to be implemented as the same thing just configured with a different parameter
Test to be done in the lab (using a signal generator) where 1 system is set to capture and the other set to freeze and validate that the data is continuous
Update [20/09/2024]: Marek will re-setup the lab system after fiber re-installations - done and now we have 4 DOROS boxes in the lab (2 connected to the same generator)
Update [10/10/2024]: Manuel planning to do a freeze on 1 box and a capture on another and make sure that the sinewave (both inputs coming from the same output of a signal generator) is continuous
Locking the gain during VdM scans
issue with event subscription to lumi server (Sat 18th May) has been fixed
proper fix should be done at the CCDE level, but either putting the subscription on one of the ordinary devices or having a script that makes sure that the on-subscription event is in the instance file could also be done as a temporary measure to guarantee the quality of the data for the experiments
Update [11/07/2024]: implemented in CCDE so, not an issue anymore
Update (11/07/2024): In one of the MDs in MD3 they want to use capture -> request is to have SDDS files to be analysed. Trigger has to be BST. Tested on the BI side for now but will be soon tested together with ABP
Update [11/07/2024]: Agreed to evaluate whether this version works and aim for deploying it for good during the next TS
Output format to be delivered to and processed by ABP
Update [20/09/2024]: Ongoing work [Manuel]
Update [10/10/2024]: Javier developed a UCAP node to create HDF5 files used by ABP to analyse data offline - small issue to discuss whether the re-arming should be automatic (could be implemente either in UCAP or FESA or anywhere else) ... this is not critical at all
Outlook for DOROS sw work
Quantify the RT performance of the FESA class
An idea would be to use Mathieu's python code which inspects (calculates statistics) the navigator's UDP diagnostics packets from the FESA class
Update [11/07/2024]: Elif will have to change Mathieu's python script that uses FESA diagnostics to do an RT characterization of any FESA class
Update [10/10/2024]: Elif showed diagnostics timestamps data, from lab systems, saved to csv files using Mathieu's script - GOAL IS TO REPEAT THIS EXERCISE DURING THE NEXT TS AND DURING THE EYETS24/25 TO CHARACTERISE (RT) OPERATIONAL SYSTEMS
Chart present design and propose refurbishment
[11/07/2024]: Elif has started making UML diagrams of the DOROS class using a script of her own + DrawIO. Ongoing work
Update [20/09/2024]: Elif will finalise UML diagrams and is working on Mathieu's RT perfomance diagnostics tool
Update [10/10/2024]: Elif showed UML diagrams on the present code. The analysis will continue and, depending on her availability (work on SoC + HL BPMs), a new code structure may be proposed
There are minutes attached to this event.
Show them.