Present
Jose, Mark, Wilfried, James (CERN), Christian Pfeiler, Guido Schiergers (DRAKA / Prysmian )
Meeting
Specififcation for the cable:
DRAKA do not have a cable in their catalogue that meets this specification.
Closest cable to the spec. is rated to 20kV - same cable that we already use for the PS & SPS BGI's ( SCEM 04.31.51.775.2 ).
This cable was tested to 50kV, but DRAKA mentioned that their test equirement is limited to 50kV.
DRAKA agreed to propose a technical design by the end of next week (W46).
Minimum order quanity for a new cable design is 1.5km.
Question of how to validate cable - CERN proposed in-house test of a prototype cable (ABT have the equipment.)
DRAKA point out that we would need to test at least a few hundred meters of cable for a meaningful test.
Post Meeting
Wilfried pointed out that we have a 60kV rated cable from Heizenger, which is halogen & smoke free - but not fire retardant.
Wilfried contacted Jose to draw his attention the Heizenger cable. Jose commented that it's only the outer jacket that is not acceptable (PVC) and will contact the company to see if a version could be produced with an alternative jacket material.
Wilfired proposed to validate the DRAKA 20kV cable - available in the CERN stores - with the ABT(?) test facility.
We could also think to test the full chain in the lab with the PS-BGI Vertical.