TB: Wire Scanners magnetic drive oscillation
Review of the issue and proposed solutions
Actions
1. Identification of the 1st resonance would be important even if it has been pushed way beyond 1GHz (we still have at 4.8GHz quite some power. This needs to be simulated (increase the range of the simulation between 6 and 10GHz)
2. In addition to previous point data should be collected with the prototype installed in this YETS: use of the additional port to measure the beam spectrum or at least coupled power (same power meter used for shottky?)
3. Additional materials to be checked like shapal
4. Is NEG compatible with running at 180 Degrees most of the time? To be checked potential electrical changes in the electrical properties
Notes about plans:
It is agreed that the hybrid+ will stay in parallel to the new system as it does not require additional work.
Legacy systems will be removed leaving only the new and the hybrid+.