104th Impedance Working Group meeting (6L2 module, PS pick-up head)
Minutes of 104th IWG meeting
Date: 2/9/2025
Present: Chiara Antuono, Michele Bozzolan, Sergio Calatroni, Heiko Damerau, Miguel Díaz Zúmel, Giorgia Favia, Ivan Karpov, Patrick Krkotic, Elena Macchia, Nicolas Mounet, Michela Neroni, Chiara Pasquino, Hermann Pommerenke, Leonardo Sito, Christine Völlinger, Carlo Zannini.
Review of minutes from 103rd meeting
Christine reviews the state of the actions from the 103rd meeting:
ACTION for new optimized crystals in TECA (IWG):
Carlo has started looking at the model and needs some further work.
ACTION for LESS treatment:
The recommendations from Lotta will be followed
ACTION (IWG): to provide with a comment for the ECR on LS4 upgrade of vacuum configuration in experiments:
The ECR has not yet been released
PS compact pickup analogue acquisition upgrade (Michele Bozzolan , Michela Neroni)
· Goal: consolidate PS BPM cabling/analog electronics with a new high-impedance head amplifier to improve maintainability and low-frequency signal quality; verify no adverse beam impact.
· Scope: pickups remain as-is (shoe-box electrostatic type in pumping manifolds); only the head assembly + electronics change. Affects 43 BI trajectory pickups and 2 RF radial-loop pickups.
· Current (“TMS”) setup: 50 Ω input amp; pickup sees ~200 Ω via 1 ns 50 Ω line; in service since 2006.
· New (“Hi-Z”) setup: frequency-dependent input; high impedance at low f; ~resistive ≈175 Ω above ~50 MHz; uses 1 m 75 Ω cabling to the electronics.
· Simulations: impulse response to a σ=0.5 ns beam shows no significant differences among TMS vs Hi-Z (1 m/2 m). Residual damped oscillation, mainly from the unmatched 1 ns line.
· RF measurement setup: manifold with pickup measured using coax probes in two configs (TMS head vs new Hi-Z head). Expected structure resonances lie above ~1 GHz; a ~1.16 GHz mode appears on-axis.
· Results: On-axis and side-axis probe scans overlay between TMS and Hi-Z when probe coupling is matched; any slight differences trace to probe coupling variations.
· Wire tests: small discrepancies seen with Hi-Z attributed to unstable finger contact on the pickup back side (confirmed in simulation).
· Conclusion: Switching to the Hi-Z head changes only the head/electronics; manifold + pickup resonances are unchanged, so no beam impact is expected.
Discussion
Michela : only geometry is considered in the simulations (not the electronics). In the measurements, the electronics are included.
Michela: the small difference between the two heads (in measurements) seems to be due to the unstable fingers contact. She did some simulations varying the contact that confirm that hypothesis (slide 20).
Heiko warns Michele that the new configuration has higher DC input impedance. In case electrons charge up the electrodes, they may discharge with more difficulty in this new configuration.
Heiko also asks about how reproducible the Zin is, in the new configuration. It seems to be more dependent on the input capacitance, compared to the previous configuration.
Vacuum module failure in 6L2 (Carlo)
The power deposition that could have caused the failure of the vacuum module in 2023 has been estimated.
The ID212 failed in 2023, due to localized heating that melted the spring. Two studies were done:
· Thermal studies, assessing how much deposited power is needed to cause failure of the spring
· Estimations of deposited power in the spring, based on impedance simulations, depending on the quality of the electric contact of the fingers :
o In the conformal case (perfect contact), the deposited power is below 10mW and is not compatible with a failure of the spring
o In the non-conformal case, relevant power is dissipated. There is incertitude in the calculation, due to (1) frequency shift of resonances and (2) how imperfect the contact is
Carlo informs that VSC is presently doing a reconstruction of the situation based on the X-ray pictures.
To statistically compute the deposited power in the spring, the following has been considered:
· Different frequency shifts of the resonances
· Different cases of contact of the RF fingers (bad contact of the fingers in few locations or in more locations )
The results of the statistical study are shown in the presentation.
The study was conducted for 8b4e beams, with different number of bunches. Statistically, for the 8b4e, running up to ~700 bunches does not pose more risk that in the operational case.
This study was conclusive to limit the intensity during the 8b4e MD, under the premise that, with the 8b4e, we should not take more risk than with the operational case.
Discussion
Carlo is asked if using longer RF fingers would guarantee a better contact. Carlo replies that experts have not agreed on whether that assumption is correct or not.
Sergio asks Carlo if the beam has an offset, in the simulations. Carlo replies that yes.
Patrick mentions that some septa magnets also have a peculiar shape of the RF fingers, and these may also be or have already been a potential source of issues.
In the past, it was mentioned that the way the RF fingers are manufactured may have some impact: the RF fingers are cut and formed in a metal sheet, and then, the metal sheet is rolled in a cylinder, then attached to the beam chamber. When the sheet is rolled, the two fingers at each end of the sheet end up one to each other, but the gap between them may be bigger than the gap between the rest of the fingers, if the design or the manufacturing is not precise. Christine asks about the influence of that gap between the fingers that close the roll. She asks if a bigger gap may be a cause of heating.
Carlo and Chiara reply that this was simulated (one of the gaps is higher) and, by itself, this defect does not result in enough power to cause failure of the spring. To have such high power levels, a contact degradation is needed.
Therefore, that defect alone is not the cause of the failure. Still, this plays some role and has some influence in the deposited power.
AoB: Broadband contribution from MKI-cool impedance (Michela)
It has been found that the imaginary part of the beam coupling impedance (𝐈𝐦𝒁) of the MKIs (both non-cools and cools) is not included in the LHC impedance model.
With Ivan, she has found some sources of information about the 𝐈𝐦𝒁 of the MKIs:
· Hugo Day’s thesis, which quantifies 𝐈𝐦𝒁 /𝒏 ≈ 𝟏 𝐦𝜴
· Latest CST model, developed in ABT group, which quantifies 𝐈𝐦𝒁 /𝒏 ≈ 2 𝐦𝜴
Studies are still ongoing to better assess the 𝐈𝐦𝒁 of the MKIs, which then should be included in the LHC impedance model.
Discussion
Carlo suggests looking at the measured transverse impedance. From the data of zero displacement, the imaginary part could be computed, using the log formula. Michela points out that it may be noisy.
Giorgia adds that getting information from the PSpice model seems complicated, not very reliable and hard to benchmark. Also, the beam is presently not included in the Spice model.
Michela adds that the 𝐈𝐦𝒁 was also estimated from fitting the longitudinal data of the real part of the impedance to a resonator model. Leonardo points out that this may not be sufficient, since it does not consider the broadband contribution.
Miguel asks about the broadband impedance computed from the beam measurements. He asks whether the results are similar in beam 1 and beam 2, pointing out that the MKIs are water-cooled only in beam 2. Ivan thinks that they are similar, and Christine mentions that this is being measured in the present MD.