Annika questions
DB downtime last week, investigate the bulk image upload?
Hybrid measurement questions (to work on follow-up algorithm that can help with module assembly, pairing of hybrids based on VBD):
- At what temperature are they measured? Similar to sensor IVs, T-dependence?
- Need the measurement date / user / site / run_type similar to other measurements (currently empty / None)
- How to select quickly based on hybrid SN - the most efficient query? Can /hybridview work with query string in URL?
- Few wrong entries with V = I values (curve = straight line)
- Duplicate IV curves per hybrid, which one to take into account for follow-up? Ordered by date, SR_NO? 20WHNNNP010011
- Duplicate hybrids in DB? Twice the same object with different serial numbers (old + new specification)? Is there a list of known duplicates?
- There are sensors with two hybrid parents? https://nginx-hgtddb.app.cern.ch/viewparts/29431
- Hybrids ALTIROC3/A Version label, is it correct?