Conveners
Session 8
- Marco Di Giacomo (CEA-GANIL)
-
John Lyles16/09/2026, 08:35Solid state systemsOral presentation standard (25 min)
The Los Alamos Neutron Science Center uses a room temperature coupled-cavity linac to accelerate H- ions from 100 to 800 MeV. It is powered by forty-four 1.25 MW peak 805 MHz klystrons, each capable of 150 kW of average power. A prototype solid-state amplifier (SSA) feasibility study began in 2024, as reported at 13th CWRF Workshop in Oak Ridge. We are using high voltage Gallium Nitride (GaN)...
Go to contribution page -
Dr Longbo Shi (Institute of Modern Physics, Chinese Academy of Sciences)16/09/2026, 09:00Solid state systemsOral presentation standard (25 min)
The Institute of Modern Physics (IMP), Chinese Academy of Sciences, has recently developed a series of compact 750 MHz pulsed solid-state power amplifiers (SSPAs) with a total output power of 1.8 MW. These pulsed SSPAs with rated power ranging from 200 kW to 400 kW have been developed based on gallium nitride (GaN) 5 kW and 10 kW single transistor. This report will present the overall design...
Go to contribution page -
Dr. Rutambhara Yogi (European Spallation Source (ESS) ERIC)16/09/2026, 09:25Gridded tubesOral presentation standard (25 min)
The first section of the ESS superconducting linac is the Spoke linac. It consists of 26 superconducting Spoke cavities resonating at 352 MHz, installed in 13 cryomodules. Each Spoke cavity is powered by an RF Power Station (RFPS), with a maximum output power requirement of 400 kW. To achieve this power level, the outputs of two amplifiers based on TH595A tetrodes are combined.
Go to contribution page
Twenty-seven... -
Mr Gino Cipolla (CERN)16/09/2026, 09:50Gridded tubesOral presentation standard (25 min)
The LHC Crab Cavity System is powered by dedicated 400 MHz high-voltage RF stations based on IOT amplifiers. These systems were designed to provide reliable and stable RF power while meeting the stringent availability and machine protection requirements of the LHC and future HL-LHC operation.
Go to contribution page
The installation of the RF infrastructure in the LHC galleries required the integration of...