Final Cooling Solenoid - Progress Meeting
In Attendance: @Arjan Verweij, @Audrey Jade Ventura, @Frantisek Sanda, @Konstantin Weindel, @Raphael Unterrainer, @Tim Mulder, @Alessio Simoni, @Oscar Sacristan De Frutos, @Bernardo Bordini
Compression Testing
-
Stainless steel dummy testing has been completed.
-
Testing is now ongoing with the copper dummy.
-
The coil is currently in metrology and is expected to be returned next week or the following week.
-
Testing campaigns:
-
-
Universal testing machine setup with instrumentation mounted on top of the coil.
-
Manual setup with an observation window, allowing the coil to be visually monitored from above during testing.
-
Data Evaluation
-
Wrap-up of measurement setups used over time.
-
Current status:
-
-
Semi-automated measurement and evaluation pipeline implemented.
-
Measurement resolution is sufficient to detect deviations from nominal behavior.
-
4.2K Measurement Setup - Final Design
- Final setup presented.
- All pieces are in production with Jorge now. First pieces are being produced as we speak.
Grenoble Test (20 T Background Field)
-
Simulations performed at higher temperatures using the original pancake architecture.
-
Results indicate a temperature limit of approximately 40–45 K to reach the critical current.
-
Mechanical considerations:
-
-
Structural protection and casing are required. This includes:
-
An outer shell.
-
Internal support to withstand both inward and outward forces during cooldown and ramping of the background magnetic field.
-
-