IBDRS Boris Tube proto 6 tests and improvements for RILIS

→ Europe/Zurich

Presents: Roland, Pavan, Sebastien, Lukas, Timo and Stefano

 

  • Pavan comments about test report (EDMS 3546993)
    • 3 Boris tubes last versions (without glue) are compared :
      • without conductive paint
      • with conductive paint
      • with conductive paint and with triple point filler polyurethane
    • each modification improve the electrical behiavour
    • Roland: PD defects are unavoidables, if the insulator support the DC HV definded it can be consedered as OK
      • in our case, the last variant support 90 kV DC for 10 hours, it can be considered as validated (our nominal is 60 kV)
  • Rilis insulator:
    • some improvement will be done for the next Rilis insulator:
      • the insulator is directly glued on the internal Al tube during wiring procedure by the supplier (no air gap)
      • the conductive paint will be applied only on ground side and in the extremities
      • we fill it with polyurethane like on the picture (only ground sides)
      • the end of the HV sides shall ber rounded like on the picture
      • Roland and Pavan aggree to test the DC HV 90kV in their lab, but to be checked if there is enough space inside the cage, if not outside with a "balisage"
    • Timo will update the drawings
    •  

 