HiDRa meeting

→ Europe/Zurich
Zoom Meeting ID
67952279705
Host
Gabriella Gaudio
Useful links
Join via phone
Zoom URL
    • 14:00 → 14:10
      Introduction 10m
    • 14:10 → 14:30
      HiDRa commissioning at Pavia 20m
      Speaker: Nicolo Valle (INFN Sezione di Pavia (IT))

      HiDRA back in operation:

      • Calorimeter and counting room installed in Pavia's lab
      • Work with Milano/Insubria group last week to repower the system
      • FERS: 
        • 16 FERS currently mounted and in operation. Modules 409 and 410 (4 FERS) not equipped, because of: (i) lack of LV supply channels; (ii) boards used in Milano for specific tests
        • Mapping unchanged wrt test beam
        • 12 FERS powered with CAEN Main Frame + 4 (+1: data concentrator) with power adapters
        • Instabilities observed when powered ON (possibly due to improper firmware initialization) ; it seems solved using slower voltage ramp up
        • SiPM HV turned ON for all connected channels with no issues
      • LV boards:
        • One CAEN A2552 (8 channels) bought new
        • One CAEN A2519 (8 channels) on loan from Bologna -- cables adapted with D-sub connectors
        • --> only 4 channels left to PMTs -->  ~12 PMTs amplifier boards can be operated
      • Trigger:
        • Trigger board in operation. Arduino fw improvements can be tested
        • 2 scintillators used to trigger on cosmics: O(1 Hz), in principle* with low noise  (* = no in-depth analysis to see if muons were there)
        • 50 ns total latency between scintillators and FERS --> ok, boards are working in triggered mode
      • DAQ:
        • EuDAQ used during TB restarted and working as it was in June
        • Few k events taken
        • Fixing priorities, cleaning up, then proceeding with development
      • Firmware:
        • Data Concentrator fw upgraded, from 2026.4.1.1 to 2026.11.3.1
        • FERS fw upgraded, from v7.8 to 9.1
        • Janus 5 installed on DAQ machine
        • Link synchronization tested only a few times: ok, no issues (but no evidence of improvements so far, given the very few attempts) --> will be tested as next step
        • Updated FERSlib to be imported in EuDAQ... debug may be needed…
      • Status:
        • System is OFF. We are rearranging the setup in the lab for a more stable configuration

       

      Electromagnetic module: 

      • Equipped with one spare FERS. Data taken with both Janus and EuDAQ
      • No PMTs. The instrumented 64 channels can be used for calibration studies
    • 14:30 → 14:50
      50 Hz noise in triggers 20m
      Speaker: Ruggero Turra (Università degli Studi e INFN Milano (IT))
    • 14:50 → 15:10
      Fast Simulation of Shower Development in IDEA Detector Dual Readout Calorimeters 20m
      Speakers: Hamza alhaddad, Iacopo Vivarelli (Universita e INFN, Bologna (IT))