Mr Sandro ROSSI (CNAO)19/10/2012, 08:45
-
Marco Silari (CERN)19/10/2012, 08:55
-
Marco Pullia (Fondazione CNAO (IT))19/10/2012, 09:10
-
Mario Ciocca19/10/2012, 09:40
-
Marco Caresana (Politecnico di Milano)19/10/2012, 10:00The aim of the measurement is to test the instrument prototype LUPIN around the CNAO accelerator. The interest is to measure in the synchrotron hall, in the treatment rooms, in the mazes and outside the shielding walls. The beam delivery should be pulsed with the possibility to vary the beam intensity and the repetition rate. The results will be compared with passive measurements performed...Go to contribution page
-
Stefano Agosteo (Politecnico di Milano)19/10/2012, 10:20A monolithic silicon telescope (MST) consisting of a surface ΔE detector 2 µm in thickness coupled to an E detector about 500 µm in thickness made out of a single silicon wafer was recently proposed for the microdosimetric characterization of hadron beams. The ΔE detector is segmented in a matrix of micrometric cylindrical diodes (about 9 µm in diameter, 2 µm in height). The silicon...Go to contribution page
-
Michele Ferrarini19/10/2012, 11:00The aim of the measurement program is to test and characterize the CR-39 detectors for environmental and personal dosimetry in high energy neutron and mixed fields. The measurements may also be based on LET spectrometry, and may take place inside the synchrotron hall or the treatment rooms for environmental and personal dosimetry. Some tests may also be performed for LET spectrometry and...Go to contribution page
-
Fabrizio Murtas (Istituto Nazionale Fisica Nucleare (IT))19/10/2012, 11:20The aim of the project is to test a GEM detector for beam monitoring in hadrontherapy facilities, namely to control the characteristics of the beam before entering the patient, its fragmentation and to monitor the non-therapeutic dose to the patient. GEM detectors have already been used for beam monitoring at CERN and at the Frascati INFN Laboratory, for flux measurements of neutrons (n_TOF at...Go to contribution page
-
Fabrizio Murtas (Istituto Nazionale Fisica Nucleare (IT))19/10/2012, 11:40Neutron production at hadrontherapy facilities is a source of non-therapeutic dose to patients. To study this dose it is necessary to measure the neutron fluence and spectra. Our proposal is to couple a GEM detector with several types of neutron converters. Using this device, we can then characterize components of the neutron spectrum and investigate the detectors reliability as a neutron...Go to contribution page
-
Jan Jakubek (Czech Technical University (CZ))19/10/2012, 12:00Semiconductor pixel detector Timepix can be used to measure the geometrical characteristics of the beam, such as the lateral penumbra, the beam flatness and the beam broadening while passing through different samples. 1. Investigations of Secondary Ion Distributions in Carbon Ion Therapy Using the Timepix Detector The purpose is to investigate the potential for beam monitoring by detecting...Go to contribution page
-
Stefano Agosteo (Politecnico di Milano)19/10/2012, 14:00Centre for Medical Radiation Physics is developing quality assurance (QA) instrumentation for radiation therapy. Two types of experiments are proposed on C-12 and proton therapeutic beams. 1. High Spatial Resolution SOI Microdosimetry on proton and C-12 beams. Microdosimetry based RBE study on C-12 and proton therapeutic beams along the Bragg Peak (BP) and SOBP (Spread-Out -BP) using SOI...Go to contribution page
-
19/10/2012, 14:20A multi-element TEPC detector consisting of 61 elongated cylindrical cavities drilled in a 5 cm by 5 cm cylindrical block of A-150 tissue equivalent plastic filled with low pressure tissue equivalent propane gas to simulate a 2 micrometer soft tissue site has been constructed and characterized for radiation protection neutron monitoring in nuclear power plants. However, by operating each...Go to contribution page