Study of Proximity Focusing RICH with Silica Aerogel Radiator

23 Feb 2007, 14:55
20m
HS1 (Univ. of Technology)

HS1

Univ. of Technology

Wiedner Hauptstrasse 8-10 Vienna, Austria
Contributed Talk Session 10

Speaker

Ichiro Adachi (KEK)

Description

Proximity focusing RICH based on silica aerogel Cherenkov radiator has been developed for new particle identification device in the Belle detector upgrade. To further improve detector performance, new concept for Cherenkov ring imaging has been introduced, where multiple aerogel layers with different indices are accumulated to increase detected photoelectrons without making a signle photon resolution worse. By constructing a prototype counter, this idea has been validated in a test beam experiment, and we achieved 5.5 σ π/K separation at 4 GeV/c with more than 9 photoelectrons.