The HADES tracking system consists of 24 trapezoidal, planar 6-layered lowmass multi-wire drift chambers (MDC) symmetrically arranged in six sectors, forming four tracking planes (I-IV) of increasing size. The analog part of the readout of the drift cell signals is done via ASD8-B (Analog Shaper Discriminator ) chips for differential amplification, shaping and discrimination. The chips deliver logical signals with variable width, equivalent to the time the shaped signal exceeds a given threshold. The logical signals are fed to TDC chips allowing to measure the Time-over- Threshold (ToT) of the signal. A method has been developed to derive the energy loss deposited in the drift cell from the drift signals ToT. Special attention has to be paid to the unfolding of the dependencies of the ToT from the track topology, the electric field and the different cell geometry thus allowing to average over all drift cells taking part in a reconstructed trajectory. An energy loss resolution of about 10% is achieved for minimum ionizing particles and 7−8% for strong ionizing particles. The results are comparable to standard energy loss measurements via the integrated deposited charge.