ADC Weekly

→ Europe/Zurich
ATLAS Distributed Computing (CERN)

ATLAS Distributed Computing

CERN

Alessandro Di Girolamo (CERN), Andrej Filipcic (Jozef Stefan Institute (SI))

Grid production  Jose
next week to know more about MCORE
plot in slide 3 is perfect
Kaushik: low priority jobs sometimes were used to "fill the holes". have you asked to phys coord to have this kind of jobs "in your pockets"?
Jose: there were nothing to do in the past weeks, we will ask for the this summer.


ProdSys2 commissioning
Andrej: if you want to run DC14 with this, how do you see?
Jose: maybe we won't be ready fully, but we can use prodsys1+prodsys2.
Andrej: we can run the pile in ProdSys1 for 8TeV, and simul in ProdSys2
Andreu: not sure, they have
Jose: reco+pile for already simulated hits , 13TeV completely in ProdSYs2


Emmanouili:
reprocessing campaign with ProdSys1, before the second step there was the first step to be finished. one tier1 slow was causing slow down to everyone.
Andrej: this was to "finish" one period, then remove intermediate , for disk space reason, then go to the next period.
Emmanoeli: can ProdSys2 help?
Andrej: not right now, maybe in the future. Today the priority is to provide functionality of ProdSys1


Rucio commissioning - Tomas
Hiro: can I stop the 2 LFC in BNL?
Tomas: we asked CERN to stop the machines but keep them.
Hiro: will stop the daemons.
Armen: concerning deletion rate. I was checking in US T2. typical is about 3-5Hz. now is 0.5 Hz, 10 times less. Is there anything?
Not related to this.
in the past weeks we had problems with OpenSSL between various nodes and Central Catalog.

slide3:
how much history? 1 week, 2 weeks, what?

Emmanoueli:
criteria how to include you propose today are stricter than T2D
Andrej: more request. we need ON/OFF/AUTO.
we have simul jobs, pile jobs.T2s would receive only low amount of redo jobs. MCP may work very well for simul, but bad for pileup/reco jobs.
would be nice to distinguish high/low I/O
usually the input transfer is quite fast. but the finishing part is much longer. it may happen that if we run too much automatic, one T1s has too many finished/transfrerring jobs which can't be digested, and then you've timeout.

possibilty to exclude one cloud from MCP when too many "transferring" are there.

Alexey: check the Tier1s with best T2Ds, in this way you can balance the distribution of "how many T2Ds are MCP for a Tier1". because if you just sort the top T1s for each T2D then you may end up in few Tier1s with many T2Ds, others with few.

next week we will have another presentation with all the comments.


ADCoS report: Wahid
SiteServices issue - Tomas: not clear yet.

next ADCoS expert we have Hiroshi Sakamoto

 

There are minutes attached to this event. Show them.
    • 15:40 → 15:55
      Grid Production news 15m
      Speakers: Bruno Lenzi (CERN), Claire Gwenlan (University of Oxford (GB)), David Michael South (Deutsches Elektronen-Synchrotron (DE)), Jose Enrique Garcia Navarro (Instituto de Fisica Corpuscular (ES)), Nurcan Ozturk (University of Texas at Arlington (US)), Paul James Laycock (University of Liverpool (GB)), Wolfgang Ehrenfeld (Universitaet Bonn (DE))
      Reprocessing - DC14
      Slides
    • 15:55 → 16:20
      Hot topics
      • 15:55
        ProdSys2 commissioning - status update 10m
        Speakers: Claire Gwenlan (University of Oxford (GB)), Jose Enrique Garcia Navarro (Instituto de Fisica Corpuscular (ES)), Wolfgang Ehrenfeld (Universitaet Bonn (DE))
      • 16:05
        Rucio migration - status update 10m
        Speakers: David Cameron (University of Oslo (NO)), Vincent Garonne (CERN)
        Slides
      • 16:15
        CVMFS client upgrade needed! 5m
        From: Andrea Manzi <Andrea.Manzi@cern.ch> Subject: CVMFS client upgrade Date: June 13, 2014 10:14:03 AM GMT+02:00 To: "wlcg-ops-broadcast (WLCG Operations Broadcasts)" <wlcg-ops-broadcast@cern.ch> Dear Site Managers, during the last WLCG ops coord meeting it was presented the plan for the upgrade of the CVMFS installation servers hosted at CERN [1] from v 2.0 to v 2.1, starting from August the 5th. Before the servers upgrade (by the end of July) we should make sure that the CVMFS client deployed on the WLCG infrastructure are upgraded to the 2.1.19 version [2] , released on 28th May. Be aware that old versions 2.0 and < 2.1.19 contain known bugs that have been fixed on the latest version, therefore the upgrade is highly recommended. thanks for your collaboration regards Andrea Manzi WLCG ops team [1] https://indico.cern.ch/event/321389/contribution/5/material/1/0.txt [2] http://cernvm.cern.ch/portal/filesystem/cvmfs-2.1.19
    • 16:20 → 16:40
      plan on automatically define MultiCloudProcessing MCP 20m
      Speaker: Artem Petrosyan (Joint Inst. for Nuclear Research (RU))
      Slides
    • 16:40 → 16:55
    • 16:55 → 17:00
      AOB 5m
      • network reports (if any)
        - for T2(D)s against T1s - for T1s against T2Ds
      • Analysis Availability Reports