This is the list of things to do from today's meeting.
I put in red the things that look like the calculation is wrong, in yellow improvements (i.e. things that are not wrong but could be better), and the rest issues that are less urgent. My idea is to fix the red and yellow for this release, and do the other features for the next version.
- Check magnetic field gradient: it looks too large
- Check Inductance calculation: off by ~ x10--15
- Report:
- Generate images of the report sheets
- Add units to every table
- Make the summary on the first report page a table
- Reduce the number of sheets
- Remove unused physics
- If we have many coils don't use the individual sheets
- Temporal scales rework:
- Quench time (from ~ 2x quench time to 0)
- Precursor time (take all the negative MF)
- After quench time (take all the positive MF, to see the maximum voltage)
- Add tables to the report plots
- Dynamic images of magnet and its Vtaps layout (based on the magnet's name)
- Uniform y-scale for the voltage segments between different files
- Probably can be done at the same time as MFMQD
- Add quench detection thresholds to have 5 different levels
- Fit current as I = I_0 exp [ f(L/R, t) ]
- Rework the segment quench detection to not require offset
- Multi File Manual Quench Detection (MFMQD)
- Use always and always save the information
- Add a way of fixing the information from the software
- Check if we're doing "register" or "load"
- Add the capability of manually choosing the quench location
There are minutes attached to this event.
Show them.