17–22 Jun 2018
Europe/Zurich timezone
15th European Vacuum Conference

The multistage differential pumping system in CIADS

19 Jun 2018, 16:50
1h 30m
Main Lobby (CICG)

Main Lobby

CICG

Poster Vacuum in Accelerators Poster Session Tuesday

Speaker

Mr Peng Zhang

Description

CIADS is short for China Initiative Accelerator Driven System, consists of intense-beam proton accelerator,spallation target and subcritical core.The multistage differential pumping system is a part of the large and complex vacuum system of CIADS which is between intense-beam proton accelerator and spallation target. The working pressure of spallation target is 5.0E4Pa for He,however, the pressure of beam line which links the accelerator is 1.0E-6Pa.So ensuring the proton bean to bombard the spallation target and obtaining the pressure vary from 5.0E4Pa to1.0E-6Pa is an important research task.
The multistage differential pumping system with ten orders of magnitude pressure differential is obtained, of which working pressure spans all areas of vacuum, including viscous, transition and molecular flows. Based on the principle of differential vacuum system, this poster introduces the choices of materials, vacuum measurement elements and pumping system.In a few days, the availability of pumping system will be tested. The calculation and the design of ten-stage differential vacuum system has been finished already.

Primary author

Mr Peng Zhang

Co-authors

Mr Chuanfei Hu Mr Junhui Zhang

Presentation materials

There are no materials yet.