Session 4 : Pulsed measurements and online monitoring and analysis
- Etienne Carlier (CERN)
"Measurements and diagnostic of kickers pulses through ADC systems"
ALBA is a 3rd generation synchrotron light source operating for users since 2012. Since 2014 the storage ring is operated in top-up mode with injections every 20min. The injection into the storage ring is performed using a septum and a closed bump created by 4 kickers. The kickers must have identical, shape, amplitude and be...
“Pulse Current Monitoring for Fast Pulsed Magnets at BESSY II and MLS light sources”
The BESSY II and MLS storage rings are 3rd generation light sources. While the first one is usually operated in the top-up-injection mode, where injection efficiencies above 90% are required, the second one requires every 6 hours a dedicated injection procedure to refill for user operations.
To support the...
"High stability resonant kicker system for Swiss Free Electron Laser (SwissFEL) at Paul Scherrer Institute"
To increase SwissFEL efficiency, a double bunch operation is planned in order to serve simultaneously two experimental stations at the full linac repetition rate. The kicker system has to separate two electron bunches that are 28 ns apart and send them to two separate beamlines. Since...