Modes and APIs for SPS Orbit system upgrade

Europe/Zurich
866/1-A04 (CERN)

866/1-A04

CERN

15
Show room on map

Present: V. Kain, J. Wenninger, M. Wendt, A. Boccardi, A. Topaloudis, M. Barros, L. Jensen

Supported modes for OP:

  • Injection trajectory for up to 16 injections per user
    • First injection has all gates enabled (assume empty ring)
    • Subsequent injections with OP gate selection (PPM setting)
    • Injection pre-pulses used to trigger (SPS BST)
    • Data published after each injection
  • Capture (one acquisition per user)
    • Slots and number of turns OP setting (PPM)
    • Trigger with msec delay from injection prepulse or start of cycle
    • Data published at end of acquisition
  • Orbit data (basis = 1kHz average of all slots)
    • Continuous IIR filter with data stored to DDR (dual-port)
    • Acquisition properties:
      • Server action with filters (as for BPMOPOS today) (Get() only - not notified)
        • YASP will specify start, stop etc
      • Server action with notification (end of cycle)
        • Orbit data averaged over 10msec (fixed) for all BPMs or (two registers)
        • ‘orbitAverageDepth’ // how many samples to sum over (starting from the first sample)
        • ‘orbitAverageJump’ // how many samples to ‘jump’ between starting averages

If we want one snapshot per 10 msec you would put: depth = 1, Jump = 10

If we want averages over 10 sample every 10 msec you would put: depth = 10, Jump = 10

The new system with its operational APIs will be documented as a simple EDMS document. Lars will provide a suitable template to Athanasios.

There are minutes attached to this event. Show them.