MQXFBP1 Test Preparation Meeting

→ Europe/Zurich
2173/1-P06 (CERN)

2173/1-P06

CERN

20
Show room on map
Franco Julio Mangiarotti (CERN), Gaelle Ninet (CERN)

Open points for discussion in the test plan:

  • Ramp rate during training:
    • Standard value for short models: 20 A/s
    • MQXFA vertical test: 20 A/s
    • Required from beam dynamics: 14.6 A/s (source MCF circuit table, V8.0)
    • Baseline during training of MQXFBP1: tbc (proposal 20 A/s)
  • Maximum Acceleration rate when reaching a plateau current
    • Standard value for short models: 50-200  A/s2
    • MQXFA vertical test: 0.9 A/s2
    • Required from beam dynamics: 0.73 A/s2 (source MCF circuit table, V8.0)
    • Baseline during training of MQXFBP1: tbc (proposal 50-200 A/s)
  • Maximum allowed temperature gradient: 30 K +- 20 K
  • Maximum current allowed during training
    • TC1: Nominal + 100 A
    • TC2: Nominal or Ultimate + 100 A, to be decided after TC1
  • Power abort verification: Ramp down from nominal at a given ramp rate to demonstrate that the magnet would not quench in case of a fast power abort.
    • MQXFA vertical test: Ramp down from nominal at 150 A/s (from acceptance criteria)
    • Required in the LHC: Initial discharge ramp rate -40 A/s (crowbar 10 V)--> recommended to have a factor 3 of margin
    • Baseline for MQXFBP1: Ramp down from nominal at 150 A/s
  • Number of thermal cycles: 2
  • Current cycles: tbc (proposal as 11 T LMBHB002: around 300 cycles ramping from Inom/2 to Inom)
  • Magnetic measurements: Standard program (Machine cycle, stair step, ramp rate
  • Quench protection: Protection during training as machine baseline (CLIQ+QH), so only demonstration of protection at low current (2 kA) left, if not done with the QH checks in the preparation phase.
  • Electrical insulation test 100 K during magnet warm up 
There are minutes attached to this event. Show them.