AWAKE Run 2bc Spectrometer
CERN
Spectrometer Meeting Minutes
Participants: Matthew, David, Joe, Debdeep, Collette, Michele, Patric, Marlene
Updates & Discussions
-
Specification Document:
Currently in progress.
Action: David to share the document ahead of the next meeting so it can be discussed during the meeting. -
Magnet Positions:
-
The dipole position is fixed.
-
There is still some flexibility in the quadrupole positions. Action: David to present trade-offs.
-
-
Dipole Magnet Ramping Speed:
-
To be clarified.
-
It was agreed that the magnet will operate in DC mode (continuously powered, not pulsed), so a low ramping speed is acceptable.
-
-
Mechanical Stability:
-
Mechanical simulations have been performed, assumed to demonstrate mechanical stability of the chamber.
Action: Marlene to confirm. -
David noted that window bowing will be similar to the previous design and should not pose an issue.
-
-
Beam Parameters:
-
John provided input on the expected beam parameters to Joe and Debdeep.
Action: Share this input with David, and all involved to test diagnostic performance using these parameters.
-
-
Diagnostics & Integration:
-
Action: Reserve space for the OSR diagnostics next to the spectrometer.
-
Action: Finalize space reservation with Edu for the camera array, ensuring no interference with the magnet support.
-
Action: Discuss and define the alignment strategy for the OSR diagnostics.
-
-
Spectrometer Dipole Chamber:
-
No further comments or concerns.
Action: Marlene to launch the approval process in PLM.
-