Description
HPK p-type sensor was irradiated in steps with reactor neutrons up to the fluence of 1e16 cm-2. After each step several Edge-TCT measurements were performed during initial stage of annealing. Charge collection properties, drift velocity profiles were investigated as a function of annealing, fluence and bias voltage.