ISOLDE Seminar

Simulation and Experimental Study for a Highly Selective and High-Flux MR-ToF Mass Separator

by Franziska Maria Maier (Universität Greifswald)

→ Europe/Zurich
CERN

CERN

Description

Many experiments at radioactive ion beam (RIB) facilities suffer from isobaric contaminations, i.e. unwanted ions of similar mass. Over the years, Multi-Reflection Time-of-Flight (MR-ToF) devices have gained remarkable attention for mass separation of short-lived radionuclides at RIB facilities throughout the world [1]. They exceed mass resolving powers m/Δm of 105 within (some tens of) milliseconds. Space charge effects, however, pose a challenge for the mass separation in cases where too many ions are confined in the MR-ToF device. This limits the wider application of MR-ToF mass separators at RIB facilities. 
By performing ion-optical simulations including space charge effects, we have shown that the ion flux in MR-ToF devices can be significantly increased when changing the kinetic energy of the stored ions from 1.5 keV to 30 keV. We benchmarked the validity of the simulation approach by comparing it with time-of-flight and collision-induced fluorescence measurements with MIRACLS’ low-energy MR-ToF device [2]. Finally, the simulation code is used to configure and optimize a general-purpose MR-ToF mass separator for the ISOLDE community. Based on the simulation work, this instrument has the prospect of improving the ion flux by a factor of around 70 compared to existing state-of-the-art MR-ToF systems.
In this contribution we will present the measurements in MIRACLS’ low-energy MR-ToF device used to benchmark the simulation code including space charge phenomena. Furthermore, we will show the simulated performance of ISOLDE’s 30-keV MR-ToF mass separator, which is based on MIRACLS 30-keV MR-ToF mass separator, currently under construction for highly sensitive and high-resolution laser spectroscopy.

 

[1]
W.R. Plass et al., Nucl. Instrum. Meth. B 266, 4560 (2008)
A. Piechaczek et al., Nucl. Instr. Meth. B 266, 4510 (2008)
P. Schury et al., Eur. Phys. J. A 42, 343–349 (2009)
R. N. Wolf et al., Int. J. Mass Spectrom. 349-350, 123-133 (2013)
F. Wienholtz et al., Nature 498, 346-349 (2013) 
R. N. Wolf et al., Phys. Rev. Lett. 110, 041101 (2013) 
P. Chauveau et al., Nucl. Instr. Meth. Phys. Res. B 376, 211-215 (2015)
T. Dickel et al., Nucl. Instr. Meth. Phys. Res. A 777, 172-188 (2015)
M. Reiter et al., Nucl. Instr. Meth. Phys. Res. A 1018, 165823 (2021)
B. Liu et al., Nucl. Instr. Meth. Phys. Res. A 986, 164679 (2021)
M. Rosenbusch et al., Nucl. Instr. Meth. Phys. Res. A 1047, 167824 (2023)

 

[2]
M. Rosenbusch et al. AIP Conf. Proc., 1521:53 (2013), AIP Conf. Proc., 1668:050001 (2015)
F.M. Maier et al., Hyperfine Interact. 240, 54 (2019) 
S. Lechner et al., Hyperfine Interact. 240, 95 (2019)
S. Sels, F.M. Maier et al., Phys. Rev. Research 4, 033229 (2022)