FCC-ee tuning WG meeting

→ Europe/Zurich

 

 

Progress with Field Quality tolerances, Esmaeil

 

QY and QC quads appear to have largest impact of their b3 and b4 on DA (QY they start 100m away from IP). Reaching even 0.01 units for b4. The summary table for all studies follows:

 

 

 

Mike comments that 0.01 units in b4 is very challenging for QY (mistake on table, there should be no QC). Esmaeil comments that he should do the study magnet by magnet. Oide-san comments that b4 is not allowed so even 0.01 might not be so difficult. Mike and Jeremie mention that when imperfections from production will insert b3 and b4 errors. Oide-san mentions that 0.01 units was achieved in SuperKEKB normal conducting magnets. Pantaleo adds that stress and deformation might generate b3 and b4 and that compensating coils should be added to the lattice to cancel these aberrations. We need octupoles anyway as they are needed for the quadrupole fringe fields either at final doublet correction or chromatic sections. There are 3*8=24 QY magnets that could have special manufacturing to guarantee good field quality. Calculation is without SR and SR shrinks DA by 2/3. Rogelio suggests that locations for octupoles and sextupoles should be identified to be effective to correct the DA drops. Pantaelo reminds that adding sextupole and octupole windings to the SC QC should be possible. Mike agrees. Jeremie and Mike recall that 0.01 is hard to measure. b6 in the normal conducting quadrupole could be trimmed at designed so depends on energy (need b6 tolerance at t and Z).

 

 

Normal conducting magnet design, Jeremie Bauche & Carl Eriksson

Increasing interbeam separation to 350mm. Jermie shows that RF locations of e- and e+ are at different places while Oide-san corrects that now they are placed at same location. Rogelio comments that quadrupoles would need an extra +-1% trim for optics corrections. With the updated beam separation  and some adjustments of the pole profile the b2 and b3 of the dipoles have decreased to 0.5 units. All dipole b2 and b3 errors are within tolerances.

Arc quadrupole field quality has also significantly improved for nominal powering. However reducing current or applying magnet strength trims the magnet center shifts by max 0.12mm. b3 reaches 5 units. Further optimization of the aberrations will continue.

Carls presents implications of radiation from BS into downwards magnets. First conflict is with BC1.1, needs vacuum chamber enlarged. QC5.1 and QC6.1 need enlarged aperture. BC3.1 needs to be C shape. QC7 conflicts with the yoke and needs to have a figure of 8 shape. No conflict for QY and beyond.

 

In summary 350mm to solve the vacuum integration issue has significantly improved field quality to be within specs in the arcs with the exception of the 0.12mm and the need of an extra +-1% for optics corrections in the arc quads. First look at IR, still length and field quality is not yet regarded. Arc sextupoles are not yet looked at. IR sextupoles need to be superconducting. Rogelio comments that arc sextupoles would need quad-like, skew quad-like and orbit corrector. Jeremie would like to have specs. Pantaleo comments that quad-like coils are very difficult if close to saturation (30% margin + 20% correction margin). Jeremie agrees and add that the aperture reduction under consideration could help.  Oide-san shows a sextupole with independent coils to generate any multipole.  Hysteresis is a concern. Jeremie observes that this magnet operates in SuperKEKB at much weaker strength than what we need for FCC-ee. Rogelio asks about the possibility of making longer sextupoles, which would impact filling facto. Jeremie suggests to have a small dedicated meeting to define the sextupole specs and needs.

 

 

Superconducting magnet design, Mike

 

The cold SSS proposal with combined quad and sextupoles can reduce power consumption. Various options presented. Still to be looked at: cold BPMs and hysteresis. Mike mentioned that in the NC dipole option the trims are not yet design however Jeremie just presented a solution, that could be also used for the horizontal orbit corrector. SC SSS option needs price of HTS to reduce by factor 3-4 in the coming decades to be competitive. Jeremie adds if cost of cryoline is included. Mike replies that cryocooler cost is included but system does not need cyrolines. 

Implications of photon stoppers and impedance are presented.

Field quality of the sextupole is excellent thanks to the possibility of tuning coils!

Design of photon stopper is ongoing, it is probably too thin at the moment.

Oide-san mentions that at Z you can safe more power as one can use the tt quad slot.

 

 

 

 

 

There are minutes attached to this event. Show them.