ERAM Meeting

→ Europe/Zurich
Alain Delbart (Université Paris-Saclay (FR)), David Henaff (CEA), Guillaume Eurin (CEA/IRFU/DPhP), Laura-Iuliana Munteanu (CERN)
    • 11:00 → 11:45
      ERAM status
      Conveners: Alain Delbart (Université Paris-Saclay (FR)), David Henaff (CEA), Guillaume Eurin (CEA/IRFU/DPhP), Laura-Iuliana Munteanu (CERN)
      • 11:00
        ERAM production status at Rui's lab 5m
        Speakers: Alain Delbart (Université Paris-Saclay (FR)), David Henaff (CEA), Guillaume Eurin (CEA/IRFU/DPhP), Laura Munteanu (CERN), Laura-Iuliana Munteanu (CERN)

        Rui & co back at CERN this week

        We expect the first ERAM end of this week or next week (TBC with Alain)

      • 11:05
        Mesh pulsing 10m
        Speakers: Alain Delbart (Université Paris-Saclay (FR)), David Henaff (CEA), Guillaume Eurin (CEA/IRFU/DPhP), Laura Munteanu (CERN), Laura-Iuliana Munteanu (CERN)
      • 11:15
        ERAM gluing 5m
        Speakers: Alain Delbart (Université Paris-Saclay (FR)), Charlotte Riccio (CEA-Saclay (FR)), David Henaff (CEA), Guillaume Eurin (CEA/IRFU/DPhP), Laura-Iuliana Munteanu (CERN)

        Nothing to glue this week since no new detectors

        For next detectors:

         

        Charlotte is on holiday until August 7th. David is back on the 25th of July from Japan, Alain on the 28th and can help with gluing.

      • 11:20
        ERAM testing 10m
        Speakers: Alain Delbart (Université Paris-Saclay (FR)), Charlotte Riccio (CEA-Saclay (FR)), David Henaff (CEA), Guillaume Eurin (CEA/IRFU/DPhP), Laura Munteanu (CERN), Laura-Iuliana Munteanu (CERN)

        ERAM-27 rescan (after cleaning by Rui) started by Katharina and Shubham. 

        They had trouble finding it since it was behind another detector on the rack and was covered by a metal bar - let's avoid doing this in the future!

         

        issue on Friday - no counts seen on one pad scan, issue was that the cathode HV was not connected, easy to fix. Scan started on Saturday at noon, expect it to finish tonight. Other than the HV connection issue it is going ok.

         

        No detectors to rescan, waiting for new detectors. 

      • 11:30
        ERAM AOB 15m
        Speakers: Alain Delbart (Université Paris-Saclay (FR)), Charlotte Riccio (CEA-Saclay (FR)), David Henaff (CEA), Guillaume Eurin (CEA/IRFU/DPhP), Katharina Lachner (University of Warwick), Laura-Iuliana Munteanu (CERN)

        Noticed at the beginning of this week that after rescan of MM1-DLC1 the gas was not turned off (since July 3 to July 12).

        turned off on July 12 in the morning. Turned back on on July 13 for ERAM 27 scan

        Katharina checked how much gas was left, will upload a picture. 

        We should have enough for the upcoming scan at least.

         

        No traveller entry for MM1-DLC1 since we recently got it back from Gianmaria, Laura will create a new document.

         

        We have at least 4 FEC cards in the clean room, will pass by this week to check which numbers are left. Alain says there are another 6 or so in the cupboard.

        There will probably not be enough cards for all the new detectors, so we will "unassign" cards from the detectors which will not be mounted on the bottom TPC. 

         

        We are missing some stiffeners - discussion with Rémy and Marc at Saclay. Discussing whether they should be produced at Saclay or by an external company. So far Rémy has the plans for the stiffeners to check if they can do it. 

         

        At Saclay, received a plastic bag ("portable glove box") which would allow us to replace a detector in Japan in clean conditions. 

        Marc ordered two handles as well. 

        2 stiffeners + ERAM 15 now at Saclay to check that the procedure with the plastic bag works and define it. It would be easier if we had a table that could lift to the right height. To be checked with Rémy.

         

        Charlotte will ask cleaning company if it would be possible to clean the clean room before the end of the month (best if next week)