Working meeting on 12T HFM dipole magnetic design status
Agenda items:
- Version of current magnetic Roxie model, archiving of reference models ( L Fiscarelli)
- Update of magnetic section wrt mechanical pending local peak stress issues, interlayer thickness, update with actual simplified 12 T yoke geometry ( all)
- Magnetic design of double aperture magnet section ( all)
- On going optimization of coil heads, end spacers options, winding trials plan. (S Russenchuck )
- Interface coils geometry data format for 2D section, for 3D mechanical head modelling (mirror) (A Foussat, all)
- AOB
12 T Magnetic design status and open issues:
AF presented the summary of the status of last magnetic design of 12 T magnet and summarise situation of the open issues related to integration and last mechanical simulation of a coil section. Some high contact peak stress remains in the interlayer thickness due the outer layer wedges edge facing inner layer conductor. The last version of coil section with facing wedges in inner and outer layer shall be checked in mechanical models which should reduce peak stress.
The versions of magnetic models shall be archived for reference in the related EDMS folder CERN-0000227768.
Magnetic design models status
LF presented the various versions of the Roxie models investigated so far. Last version is v3.03 with 50 mm aperture , 6 blocks
The variant of large wedge on outer layer mid plane is an effective way to optimise the field quality.
The python interface implemented allows to export Step files for manufacture of end spacers geometry. These files require further modifications by CAD office to include fixtures. The three options of end spacers to be 3D printed with different parameters of torsion, beta, ellipticity parameters will be used to identify some best practise candidate and benchmark the model. The results of the tests should be discussed in end March to be able to progress in the coil baseline design work.
Discussion:
- Regarding the b3 harmonic correction on the double layer asembly, SR made the remark of the possible adjustability of the integrated multipole per layer by fine adjusting longitudinal position of the last outer block per coil before .
- The protection baseline of the single and double aperture magnet to be constructed shall be studied based on last results screening assessment ( QHs, CLIQ).
- It was pointed out that CLIQ system as a protection way in the dipole string present some issue related to the available redundancy of system in case of fault scenario in one CLIQ system. Also the case of CLIQ fault as main protection circuit would generate some issue of hot spot in the coupled coils
Actions items:
- Mechanical 2D analysis of the latest section needs to be updated with conductor and wedges position for reference cross check ( target beg April 24)
- Winding trials on three end spacers variants are important inputs to finalise the 3D optimised design of practise 12T coil by end April 24.
- Study and define baseline quench protection with proven technology (outer layer QH and/or CLIQ, EE also an option) for:
- Short mirror configuration magnet tested in SM-18
- Short 1 aperture magnet tested in SM-18.
Roxie reference cross section file and yoke geometry shall be approved.
- Study protection of 2 apertures magnet powered in a ring. If the reliability of the protection method (in particular CLIQ) looks challenging, then study the viability of R&D methods (like ESC).
- If ESC (or another new method) is necessary to protect 2 aperture magnets in a ring, we will discuss R&D activities to demonstrate it on the short mirror configuration.