- Compact style
- Indico style
- Indico style - inline minutes
- Indico style - numbered
- Indico style - numbered + minutes
- Indico Weeks View
Help us make Indico better by taking this survey! Aidez-nous à améliorer Indico en répondant à ce sondage !
The 244th MPP will take place in hybrid form: CCC glassbox and Zoom.
Procedure 896392 for MPS LBDS checks updated to account for the new LBDS test mode. First version reviewed by email with MPP and pending formal review & release procedure
Since YETS23/24 the LBDS is equipped with a remote test mode allowing to provide an energy signal to the system without local intervention. The changes and validation steps were agreed in [10].
# |
Action |
Description and criteria |
When |
1 |
Ensure the armed LBDS prevents enabling the test mode |
With LBDS armed, try to enable the test mode. Ensure this is not possible. Repeat for B1 and B2. |
S |
2 |
Ensure the test mode enabled prevents arming the LBDS |
With test mode enabled try to arm the LBDS. Ensure this is not possible. Repeat for B1 and B2. |
S |
3 |
Ensure the test mode enabling requires OP authorisation |
Try to enable the test mode without OP authorisation (given on device LBDS.UA63/7.TESTSEQ.CTRL.B1/2 by lhcop). Ensure this is not possible. Repeat for B1 and B2. |
S |