The detailed repair report from the Davide and Sinem list of trigger holes (BMS1A04 wasn't in list, but looks like trigger hole):
-
BML2A01.CO.Ly1.DZ1 Dp1_1 (inserto tubo)
-
BML2A01.PI.Ly0.DZ1 Dp1_2 (inserto tubo) Dp2_2 (inserto tubo)
-
BML2A01.PI.Ly1.DZ1 Dp1_2 (inserto tubo) Dp2_2 (inserto tubo)
-
*BMS1A04.CO.Ly0.DZ2 Dp1_1 (inserto tubo) Dp2_1 (inserto tubo)
-
*BMS1A04.CO.Ly1.DZ2 Dp1_1 Dp2_1 HV connected
-
*BMS4C10.PI.Ly1 broken pipe in output
-
BOL2A03.CO.Ly0.DZ2 Dp1_1 Dp1_2 HV connected DP2
-
BML1C13.CO.Ly1.DZ2 Dp1_1 Dp2_2 (inserto tubo)
-
BML1C13.CO.Ly0.DZ2 Dp1_1(inserto tubo) Dp2_1 (inserto tubo) Dp2_2 (inserto tubo)
-
BML1C13.CO.Ly1.DZ1 Dp1_1(inserto tubo) Dp1_2 HV was not reconnected on DP2 ( foam prevent, see photo)
SPS4A04.CO.Ly0+Ly1 - no leak, connected
BOS5A04.Ly0.DZ2 - no leak, connected
BOS5A04.Ly1.DZ2 - no leak, connected, HV DP1 was off
BMS6C02.PI.Ly1.DZ2 Dp2_2 (crack) - OX, reversed
BMS6A02.CO.Ly0.DZ2 Dp1_1 leak only DP2 (reduced to 0.025 mbar/s) - OX, resistor
BMS6A02.PI.Ly1.DZ2 Dp1_1 leak 0.03 mbar/s - OX, reversed
BML2C05.PI.Ly0.DZz leak 0.11 mbar/s, all corners foamed - OX
BOS4A02.CO.Ly1.DZ1 - OX, reversed
BOS4A02.CO.Ly1.DZ2 - OX, reversed
BOF5C12.PI.Ly0.DZ1 - leak 0.1 mbar/s in DP2, difficult to identify - XX, HV disconnected
BOF5C12.PI.Ly1.DZ1 -small leak (the same was in March) 0.02 mbar/s - OO
BOL6A01.CO.Ly1.DZ2 HV disconnected (it has gas leak )
BOL4A01.CO.DP1.Ly1.DZ1 leak 0.3 mbar/s - HV disconnected (DP2 HV was already off)