Lorentz angle measurements on mixed-irradiated mini strip-sensors have been performed as part of the CMS HPK Campaign. Up to now, the study covers 320µm and 200µm thick n- and p-bulk floatzone sensors at a magnetic field of up to 8T at different temperatures and after two annealing steps. In addition to that, proton irradiated magnetic-czochralski and floatzone n-on-p sensors produced by Micron were examined. This talk gives an overview of the obtained results.