The AC-LGAD technology is chosen to be used as the time of flight detector and out track for the Circular electron-positron collider (CEPC). As suggested by the CEPC board, the time of flight is urgent for the flavor physics in CEPC, especially for the k/p and k/pi separation in the low-energy part. The AC-LGAD based ToF & out tracker would be located between the TPC and ECAL which would cover 90 m2 area. The expected performance is the 50 ps time resolution and 10 um spatial resolution. This study will show the current test results with the strip AC-LGADs. The time resolution is ~37 ps and the spatial resolution is ~8.5 um.