LHC BGI Vacuum requirements

Europe/Zurich
30/2-040 (CERN)

30/2-040

CERN

8
Show room on map
Cesar Vazquez Pelaez (CERN), Giuseppe Bregliozzi (CERN), Gunn Khatri (CERN), James Storey (CERN), Mark Mclean (CERN)

Draft:

Present:

Giuceppe, Mark, James, Gunn, Cesar

Discussion:

  • Mark presents slides, starting with BGI introduction
  • Outstanding issue is how to mechanically atatch the chip to the base such that it conducts heat generated from chip operation
  • Staystick 672 is not an option (bakeout @120 degree C), see EDMS 2618330 (2021 by Swann) & EDMS 1879485 (2018 by Nicola)
  • Staystick 101, too hot for sensor, not good
  • Masterbond SUP121AO, possible option
  • Brazing and mechanical options also discussed but less preferres due to difficulties and reducing effective detection area.
  • Silicon vias (solder bond balls), possibly work but low theraml conduction surface
  • Allectra Glue4, identified as a good option -> good theraml conductivity and curing temperature ok, bakeable
  • Cesar and Giuseppe agreed to do some sample tests for the Allectra Glue4. in vacuum, bakeout/curing/outgessing
  • SY-BI will order the Allecra Glue4 and provide it to TE-VSC for the tests

 