Proposal B Meeting: Radiation Damage Studies of OE Components for the SLHC

→ Europe/Zurich
1/1-025 (CERN)

1/1-025

CERN

20
Show room on map
Cigdem Issever (University of Oxford)
Description
This meeting is dedicated to discuss the radiation protocols written by Jingbo and KK/Karl.
Jinbo's document 2
Jingbo's document 1
Karl's and KK document

SLHC Optoelectronics Proposal B Meeting, 21 June 2007<o:p></o:p>

<o:p> </o:p>

Attendances: Tony Weidberg, KK Gan, Jingbo Ye, Cigdem Issever, Todd Huffman, Karl Gill, Francois Vasey, Christian Olivetti

<o:p> </o:p>

We discussed the two documents of Jingbo (mainly the first one, but the comments raised are also applicable to the second document):

<o:p> </o:p>

1. Radiation Hardness Evaluation on OTx and ORx

2. Radiation Hardness Evaluation on serializer and deserializer chips

<o:p> </o:p>

The following questions/comments were raised:

<o:p> </o:p>

· In general the abbreviations should be explained: TIA, TP2, TP4, etc.

· Karl said that a discussion about packaging needs to be included into the document, because it will influence the test setup and also the tests details.

· Karl also would like to have a schematic/figure/description of a specific test setup such that readers have an idea how a SEE test might be performed. This could be included in an appendix. Group agreed that this is a good idea and Jingbo will put the setup used by SMU as an example into the document.

· We discussed what the dose rate steps Jingbo is mentioning in the TID tests are. It was agreed that one should increase the dose rate at each step by an order of magnitude and one should start at a dose rate which would be expected in the real experiment. In between the dose rate steps one should allow for annealing.

· It was also agreed that Jingbo mentions explicitly the used stardards (IEEE, etc.).

· Jingbo will list the different BER failures and will describe in more detail how the BER measurements are done.

· We discussed how to measure the SEU cross section as function of LET. Karl pointed out that one can get more than one point if one changes the p-i-n current. In case the BER should be measured as function of the devices’ specs (power).

· Karl suggested to make 3 paragraphs out the second paragraph in the section TID tests: Signal Quality, BER and Jitter.

· We agreed that for the early tests we will be using the 8bit/10bit standard for the signal type.

· We agreed to take out the annealing time formula.

· We agreed that if we see effects of annealing we should be study it in steps of 10C and have test at operation temperature before going into production.

· Francois said that it is necessary to assign an editor and that this person should collect the different documents and edit one document. It was decided that Cigdem will do this and she will use NASA guidelines for radiation testing of optocouplers as a base to setup the structure of this document. We agreed that there should be a section about “Test sample size” and also one about “Reliability tests”, where radiation test would be one part of it.

· Our next meeting will be on the 05.07.07 at 3pm CERN time.

<o:p> </o:p>

Agreed action points:

1. Jingbo will implement the comments and will circulate a new version in a weeks time.

2. Todd will send us a new version of the fibre protocol document

3. Cigdem will collect the documents and will edit them in one single document.

4. The structure of this document will be discussed at our next meeting.

5. Karl’s and KK’s radiation protocol document about lasers and p-i-n will be discussed at our next meeting.

6. Karl will send Cigdem the NASA guidelines for radiation testing of optocouplers.

<o:p> </o:p>

<o:p> </o:p>

<o:p> </o:p>

<o:p> </o:p>

<o:p> </o:p>

There are minutes attached to this event. Show them.
    • 15:00 → 16:00
      Discussion of Jinbo's SEE documents 1h
    • 16:00 → 16:30
      Discussion of KK and Karl's document 30m